Télécharger Imprimer la page

CAME BXV Tall Serie Manuel D'installation page 51

Publicité

Les langues disponibles

Les langues disponibles

DESCRIPTION OF PROGRAMMING COMMANDS
Display
The ESC button is for:
- exiting menus;
- cancelling changes.
- during operation it works
from a STOP command
FUNCTIONS MENU
IMPORTANT! Start programming by first performing the following: MOTOR-TYPE SETTING (A1),
OPENING DIRECTION (F54), TOTAL STOP (F1) and TRAVEL CALIBRATION (A3)
Only program functions when the operator is stopped.
You can memorize up to 25 maximum users.
When the menu is active, the system cannot be used.
F1
Total stop [1-2]
F2
Input [2-CX]
F3
Input [2-CY]
F5
Safety test
Maintained
F6
action
F7
Command [2-7]
8 8 8
The < > keys are for:
- moving from one item to another;
- increasing or decreasing values.
- after a travel calibration they allow an OPEN or CLOSE
command
NC input – Gate stop that excludes any automatic closing; to resume movement, use
the control device. The safety device is inserted into [1-2].
OFF = Deactivated (default) / ON = Activated
NC input – Can associate: C1 = reopening during closing by photocells, C2 = reclosing
during opening by photocells, C3 = partial stop, C4 = obstruction wait, C7 = reopening
during closing by sensitive safety-edges, C8 = reclosing during opening by sensitive
safety-edges.
OFF = Deactivated (default) / C1 / C2 / C3 / C4 / C7 / C8
NC input – Can associate: C1 = reopening during closing by photocells, C2 = reclosing
during opening by photocells, C3 = partial stop, C4 = obstruction wait, C7 = reopening
during closing by sensitive safety-edges, C8 = reclosing during opening by sensitive
safety-edges.
OFF = Deactivated (default) / C1 / C2 / C3 / C4 / C7 / C8
After every opening or closing command, the board will check whether the photocells
are working properly.
 The safety test is always active for wireless devices.
0= Deactivated (default) / 1=CX / 2=CY / 4=CX+CY
The barrier opens and closes by keeping a button pressed. Opening button on contact
2-3 and closing button on contact 2-4. All other control devices, even radio-based
ones, are excluded.
0= Deactivated (default) / 1= Activated
From the control device connected to 2-7, it performs the (open-close-invert) step-step,
(open-stop-close-stop), sequential, open or close command.
0 = Step-step (default) / 1 = Sequential / 2 = Open / 3 = Close
The ENTER key is for:
- entering menus;
- confirming or memorizing set values.

Publicité

loading

Ce manuel est également adapté pour:

Bxv04agtBxv06agtBxv08agtBxv10agt