Important; Adjusting The Temperature Limits; Maintenance And Care - Franke Aqrm650 Notice De Montage Et De Mise En Service

Table des Matières
Les langues disponibles
  • FR

Les langues disponibles

Important!

When putting the pressure cap in place, ensure that the tappet engages with the
corresponding groove.
12.7 Once the desired flow time has been set, put the pressure cap in place.
12.8 Reassemble in reverse order.

13. Adjusting the temperature limits

Warning!
If the hot water supply temperature is above 45°C, the - temperature limit should be
adjusted.
Failure to observe this instruction can result in injuries due to scalding.
The temperature limit is not an active scald protection.
13.1 Remove the pressure cap (see
13.2 Carefully lever off the stop ring with a screwdriver and pull off the gear teeth by hand.
13.3 Put the pressure cap in place and trigger the fitting.
13.4 Turn the pressure cap until the desired maximum water temperature is reached.
13.5 Slide the stop ring onto the gear teeth so that the stud on the stop ring is at the right-
hand end stop of the housing.
Important!
When putting the pressure cap in place, ensure that the tappet engages with the
corresponding groove (see
13.6 Reassemble in reverse order.

14. Maintenance and care

The fitting must be checked and maintained at regular intervals depending on the
water quality and in accordance with the local conditions and rules and regulations
applicable at the site.
Maintain the following components:
• Filters (see
• Non-return valve (see
• Functional element (see
Use suitable cleaning agents which do not attack the fitting in a proper manner and
rinse with water after use. High-pressure cleaners must not be used for cleaning.
Chapter
Chapter
Chapter
15.)
Chapter
Chapter
info@hygiene-shop.eu - www.hygiene-shop.eu
12.).
12.).
16.)
17.)
7
Table des Matières
loading

Ce manuel est également adapté pour:

Aqrm27420000900252000101037

Table des Matières