Exception:
1. Boats using diesel fuel as the only fuel source.
2. Outboard engines mounted externally or in compartments open to the atmo-
sphere in accordance with the requirements of ABYC H-2, Ventilation of Boats
Using Gasoline.
The bilge pump inlet shall be located so that excess bilge water can be removed from
the bilge at static floating position, and at maximum conditions created by the boat's
motion, heel, and trim.
Electrical
Disconnect power before installing or servicing the pump.
Our pump is equipped with silicone blocked, tin coated 16 gauge (1.5 mm²) wire.
Please follow the table below when extending the wires.
Recommended Wire Size
Total Wire Length (positive to pump to ground) — feet (meters)
0 – 6 ft
(0 – 1.8 m)
16 AWG
(1.5 mm²)
The electrical wiring, connections, and installation shall be in accordance with the
requirements of ISO 10133, ABYC E-11, AC and DC Electrical Systems On Boats.
This pump must be fused as follows:
GPH (LPH)
500 (1893)
800 (3028)
1100 (4164)
500 (1893)
800 (3028)
1100 (4164)
6 – 10 ft
(1.8 – 3 m)
(3 – 4.6 m)
16 AWG
(1.5 mm²)
(1.5 mm²)
Amps (Volts)
1.8 (12)
3.0 (12)
3.8 (12)
0.8 (24)
1.5 (24)
2.0 (24)
10 – 15 ft
15 – 30 ft
(4.6 – 5.5 m)
16 AWG
(2.5 mm²)
Amps (Volts)
12 Volts
2.4 (13.6)
3.7 (13.6)
4.8 (13.6)
24 Volts
1.0 (27)
2.0 (27)
2.3 (27)
3
30 – 40 ft
(5.5 – 12.2 m)
14 AWG
(2.5 mm²)
Fuse Size
14 AWG
4 A
5 A
7.5 A
2 A
4 A
4 A