Télécharger Imprimer la page

Viking MI 422 PC Manuel D'utilisation page 139

Publicité

Les langues disponibles
  • FR

Les langues disponibles

In order for docking to take place
smoothly, no no-go area must be installed
within a radius of at least 2 m around the
docking station (1).
Route the perimeter wire (1) from the edge
to the obstacle with the correct clearance
(use iRuler) around the obstacle (2) and
attach it to the ground with a sufficient
number of fixing pins (3). Then route the
perimeter wire back to the edge again.
The perimeter wire must be routed
parallel and without crossover in the
linking sections. (
12.7)
0478 131 9935 C - EN
12.9 Secondary areas
Secondary areas are parts of the mowing
area that cannot be mown fully
automatically by the robotic mower
because access is not possible. In this
manner, several separate mowing areas
can be surrounded with a single perimeter
wire. The robotic mower must be manually
taken from one mowing area to another.
The mowing operation can be initiated via
the commands "Start mowing" (
"Start time-delayed mowing" (
The docking station (1) is installed in the
mowing area A, which is cut fully
automatically in accordance with the
mowing plan.
The secondary areas B and C are
connected to the mowing area A via the
linking sections (2). The perimeter wire
must be routed in the same direction in all
areas – do not cross perimeter wires in the
linking areas.
● Activate secondary areas in the
"Settings – Installation" menu.
(
11.14)
12.10 Corridors
If several mowing areas have to be mown
(e.g. mowing areas in front of and behind
the house), these can be linked by
installing a corridor. This allows all the
mowing areas to be mown automatically.
In corridors, the lawn is only mown
along the path of the perimeter
wire. If necessary, activate
automatic edge mowing or mow the
11.5) or
corridor area manually on a regular
11.5).
basis. (
If corridors are to be installed,
switch off offset drive home
(passage) (
loops. (
The specified wire clearances are
adapted to routing of the perimeter
wire on the lawn area.
Requirements:
– Minimum width is 88 cm between solid
obstacles in the corridor area and
22 cm between paths that can be
travelled on.
In longer corridors, a slightly
increased space requirement
should be taken into account
depending on the ground
conditions. Longer corridors should
always be installed as centrally as
possible between obstacles.
– The corridor can be travelled on freely.
– At least 1 starting point must be
defined in the area of the second
mowing area. (
11.5), (
11.14)
11.14) or install guide
12.11)
11.15)
137

Publicité

loading

Ce manuel est également adapté pour:

Mi 422 pMi 422