8. FuNCTION

Via the inlet line (1) the condensate flows into the ENL 5
and accumulates in the housing (2).
A capacitive functioning sensor () continuously registers
the filling level and relays a signal to the electronic control as
soon as the container is filled.
The pilot valve (4) is activated and the membrane () opens
the outlet line to discharge the condensate (6).
When the ENL 5 is empty, the outlet line is reclosed tightly
in time before unnecessary compressedair losses occur.