Taking Out Of Operation; Connecting To The Gas Bottle - EINHELL PS 12 Mode D'emploi

Radiateur extérieur
Masquer les pouces Voir aussi pour PS 12:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 13
Anleitung PS 12 - PS 12 Niro
Use the heater only for heating purposes.
In strong winds it is advisable to secure the foot
with extra weight or to fasten it to the ground or
to stand it in a safe place.
If you are not going to use the party heater for
some time, cover the perforated plate and top
with foil in order to prevent dust and insects
getting inside.
Check that the seal on the bottle valve is present
and in good condition. Do not use additional
seals.
At the first sign of any trouble, close the shut-off
valve on the gas bottle at once.
The party heater may be operated only in
conjunction with a pressure regulator set to the
permissible outlet pressure (see the heater
nameplate and factory setting).
Turn the party radiator off before moving to a
different site. Remove the gas cylinder during
transport.
Do not kink the hose.
Install and ignite in strict adherence to the
instructions.
Important note: Use only in the open air or in
well-ventilated rooms.
Never set up the radiator in any rooms in the
home or office.
To prevent possible damage from heat, always
ensure that no other objects are placed within a
radius of 2 m of the burner or reflector.
Tips for commercial use:
To conform with BGV D34 (VBG 21), DIN 4811-3
and TRF 96, a safety pressure regulator with an
integrated high-pressure safety valve must be
installed when using this device for commercial
purposes (such as fairgrounds etc.).
This regulator is not included in the shipment.
Before placing this device into service, perform a
leakage test on all connections, either with
a leakage detection spray or a foaming agent. Do not
use an open flame.
This test must not be performed while the device is
turned on.

6. Connecting to the gas bottle

To connect the heater to a gas bottle you need the
following parts:
A standard gas bottle.
A non-adjustable, DVGW-approved pressure
regulator for a maximum capacity of 1.5 kg/h to
match the gas bottle used. Operating pressure
28.01.2005
7:15 Uhr
Seite 11
as per the factory setting.
A DVGW-approved hose pipe of sufficient length
(1,6 m) that can be installed without any kinks.
(part of the equipment)
A DVGW-approved leak detection spray or a
foaming agent.
1. Connect the union nut (1) of the pressure regu-
lator (2) to the gas cylinder valve thread (4) by
turning it counter-clockwise. Do not use tools –
these could damage the gas cylinder valve gas-
ket and leakage protection would no longer be
guaranteed.
2. Use an appropriate wrench size SW 17 and turn
counter-clockwise to connect the hose line (5) to
the pressure regulator output thread (6). When
doing so, you must hold a second wrench of the
correct size on the pressure regulator (faces are
provided on the pressure regulator for this pur-
pose) in order to stop the regulator being turned
or too much force being transferred. Use the
above tool to tighten the screw connection and to
guarantee tightness and prevent leaks.
3. Perform a leakage test on all connections with
the gas cylinder valve (3) open. If there are no
bubbles, the connection is tight and does not
leak.
7. Starting up
1. Open the gas cylinder valve (Fig. 2 / Item 3).
2. Turn knob to the large flame symbol and press
down completely. At the same time, activate the
piezo ignition repeatedly. The regulating knob
must be held down for approx. 10 more seconds
after ignition until the burner remains on. If the
flame extinguishes, do not repeat this procedure
until at least 2 minutes have passed.
3. Always turn the regulating knob slowly from the
large flame symbol as far as the stop. The device
may go off if the knob is turned too quickly.
4. To turn off the device, close the bottle valve (3).

8. Taking out of operation

To turn off the heater, move the button to „closed"
position and close the gas bottle valve.
9. Storage / Care / Repair
Remove the pressure regulator with gas hose
and check the gasket for damage. Please
contact ISC GmbH in case of damage.