TECHNICAL DATA / INSTALLATION
B
The leaf must be fixed firmily on the hinges to the pillars, must not be flexible during the movement and must move without frictions.
Before the installation of IDRO, verify all dimensions etc. (see table C1)
Gate features must be uniformed with the standards and laws in force.
The gate can be automated only if it is in a good condition and its conditions comply with the EN 12604 norm.
- The gate leaf does not have to have a pedestrian opening. In the opposite case it is necessary to take the appropriate steps, in accordance with EN 12453 norm (for instance; by preventing the
operation of the motor when the pedestrian opening is opened, by installing a safety microswitch connected with the control panel).
- No mechanical stop shall be on top of the gate, since mechanical stops are not safe enough.
A1
1.0 PRE-INSTALLATION CHECKS
Parts to install according to EN 12453 standard
COMMAND TYPE
Skilled persons
(out of public area*)
Hold-to-run operation
Impulsive - in sight
C or E
(e.g. push-button)
impulsive - out of sight
C or E
(e.g. remote)
automatic
C and D, or E
* a typical example are those doors which do not have access to any public way
A: Hold-to-run operation made by push-button ex: code ACG2013
B: Hold-to-run operation made by key selector ex: code ACG1010
C: Adjustable power of the motor or photocells to respect impact forces as indicated in
Annex A
D: Safety strips and/or other additional devices to reduce the probability of contact with
the door.
E: Devices installed in such a way that a person can not be touched by the door.
CARACTERISTIQUES
Single-phase system voltage
Motor capacity with load
Power absorption
Max thrust force
Rod retraction time (max. stroke)
Rod extension time
Max leaf length
Min leaf length
Max leaf weight
Operating temperature
Max distance between centres for mounting
holes with fully extended rod
Max stroke - standard arm
Actuator weight with oil
Oil quantity
Oil type
Protection grade
Nr. of normative cycles
Nr. of daily cycles suggested
Service
Nr. of consecutive cycles guaranteed
* In case of the leaf is longer than 1,6 meters, an electric lock must be fitted to ensure efficient closing.
1060
720
Measurements in mm
USE OF THE SHUTTER
Skilled persons
(public area)
A
B
Not possible
C or E
C and D, or E
C and D, or E
C and D, or E
C and D, or E
C and D, or E
IDRO C 27/1B
230 V±10% 50/60Hz
260 W / 310 W
1,14 A / 1,44 A
2000 N / 2500 N
17,5 s
21,5 s
2* m
0,9 m
250 kg
-20° / + 70°C
1002 mm ± 5
270 mm
8 kg
0,6 lt.
RIB Oil HC13
IP 55
30 - 17s/2s
200
60%
274
38
Not skilled
persons
50
90