ROUGH IN DIMENSIONS
Capacity, Gas and Electrical Characteristics
Model
Approx. Capacity
U.S. Gals.
Litres
HYB-90N
25
94.6
Minimum gas supply pressure must be maintained under both load and no load (dynamic and static) conditions.
Manifold Pressure is preset on the gas valve by the manufacturer; DO NOT ATTEMPT TO ADJUST!
Thermal effi ciency is 90%.
If the hardness of your water supply is more than of 12 grains per gallon (200 mg/L), if your water supply is acidic or otherwise impure,
the water supply must be treated with approved methods in order to ensure full warranty coverage. Problems resulting from the forma-
tion of scale are not covered by the warranty.
Minimum Clearance To Combustibles
Top
Front
Vent
0
0
0
This appliance must be installed in accordance with local codes or, in the absence of local codes, CAN/CSA-B149.1, the Natural Gas and
Propane Installation Code and CSA C22.1, the Canadian Electrical Code.
Not for installation in a Manufactured Home (Mobile Home).
This water heater is suitable for water (potable) heating only.
This water heater is suitable for installation in a closet or alcove.
8
All manuals and user guides at all-guides.com
INSTALLATION CONSIDERATIONS
Left Side View
Input
Gas
Gas Supply Pressure
Type
BTU/hr
Max.
in. WC (kPa)
100,000
Nat.
14.0 (3.49)
Back
Sides
0
0
FIGURE 2
Manifold Pressure
Min.
in. WC (kPa)
in. WC (kPa)
5.0 (1.25)
4.2 (1.05)
Service Clearance
Floor
Front
0
533mm (21 in.)
300mm (12 in.)
www.hotwater.com
Top View
Electrical Characteristics
Volts/Hz
Amperes
120/60
2.5
Test Pressure
P.S.I.
Sides
300