12 NXA DIGITAL AUDIO MANAGER SERIES
IMPORTANT NOTE:
The communication must be started with the client sending the first message
Otherwise, the commands from the client to the EclerNet device will be ignored.
additional information.
TYPE
PARAM1
SYSTEM
CONNECT
DISCONNECT
SUBSCRIPTION_RATE
PING
PONG
GET
ALL
POWER
PRESET
OLEVEL
XLEVEL
OMUTE
XMUTE
OVU
ALARM_PROTECT
ALARM_FAULT
PARAM2
PARAM3
[PINGPONG]
<Rate>
<Output
Channel>
<Input
<Output
Channel>
Channel>
<Output
Channel>
<Input
<Output
Channel>
Channel>
<Output
Channel>
<Output
Channel>
<Output
Channel>
SYSTEM CONNECT
See TP-NET PROTOCOL INTRODUCTION chapter for
PARAM4
DESCRIPTION
Saves the client IP address for responses and then dumps current
device status (with DATA messages)
Cancel subscriptions and terminates communication
Alive message from device
Alive message from device
Alive ACK message from client
Dumps current device status (with DATA messages)
Gets the Device Power status
Gets the current PRESET
Gets the current LEVEL of an Output Channel
Gets the current LEVEL of a Matrix point
Gets the current MUTE status of an Output Channel
Gets the current MUTE status of a Matrix Point
Gets the VU-meter value of an Output Channel
Gets the Protect alarm status of an Output Channel
Gets the self-diagnosis system alarm status of an Output Channel
25
to the EclerNet device.