GENERAL SPECIFICATIONS
RT310 is an electrical outlet tester that tests the wiring condition at an
electrical outlet, and inspects GFCI and AFCI devices. It is designed for
use with North American 120V electrical outlets.
• Operating Altitude: 6562 ft. (2000m)
• Relative Humidity: <85% non-condensing
• Operating Temp: 32° to 122°F (0° to 50°C)
• Storage Temp: -4° to 140°F (-20° to 60°C)
• Dimensions: 7.4" x 2.3" x 1.3" (188 x 58 x 32 mm)
• Weight: 8.5 oz. (241 g) including batteries
• Battery Type: 3 x 1.5V AAA Alkaline
• Standards: Conforms to UL STD.61010-1,
61010-2-030, 1436
Certified to CSA STD C22.2 # 61010-1,
61010-2-030, 160
• Pollution degree: 2
• Drop Protection: 6.6 ft. (2m)
• Ingress Protection: IP40 dust resistant
• Safety Rating: CATIII 135V
CAT III: Measurement category III is applicable to test and
measuring circuits connected to the distribution part of the
building's low-voltage MAINS installation.
Specifications subject to change.
To ensure safe operation and service of the tester, follow these
instructions. Failure to observe these warnings can result in
severe injury or death.
• RT310 is designed for use with North American 120V electrical
outlets. DO NOT connect to higher voltage electrical supplies.
• Prior to use, always verify tester operation by testing on a known
live and correctly wired electrical outlet.
• DO NOT attempt an AFCI testing event on a circuit with powered
ON equipment or devices. Remove or power OFF prior to testing.
• DO NOT use if the tester appears damaged in any way.
• The tester is intended for indoor use only.
• Other equipment or devices attached to the circuit being tested
could interfere with the tester. Clear the circuit before testing.
• This tester only detects common wiring problems. Always
consult a qualified electrician to resolve wiring problems.
• DO NOT attempt AFCI, GFCI, or 30mA ground fault testing on an
incorrectly wired outlet. Consult a qualified electrician to resolve
wiring problems.
2
WARNINGS
FEATURE DETAILS
2
3
12
11
5
7
13
1
8
1.
Power button
2.
Hazardous Voltage Warning
3.
Wiring Condition Indicators
4.
Circuit Energized / Not Energized Indicator
5.
GFCI Test Button
6.
AFCI Test Button
7.
30mA Ground Fault Test Button
8.
Power On / Low Battery Indicator
9.
Plug
10.
Battery Cover
11.
GFCI Indicator
12.
AFCI Indicator
13.
30mA Indicator