AMR PULSE W-Mbus- Mode d'emploi / User guide version V1.2

4.3. History frame

A history frame is sent every 12 hours, regardless of the frequency of data transmission.
Each history frame contains a reading of the last 12 measurements made. The measurements are organised from the most recent to the oldest.
The product records 1 value per hour except for the period of 12 hours.
To find the timestamping of measurements, the following formula must be applied:
Data 1 = history frame reception time - time tag
Data x = history frame reception time - time tag - x times the sample rate
Example:
FF 19 44 46 06 14 04 00 19 03 07 AD 02 00 00 00 00 2F 2F 01 13 00 02 08 07 00 B5 15 00 00 00 02 36 30 BF

4.3.1 Format

SOF
L-Field C-Field
M-Field
FF
19
44
46 06
08 07 00
B5
15 00 00

4.3.2 Decoding the frame

NOTE: All data blocks are coded in Little Endian
Type
Frame start
SOF
Frame size
L-Field
Control
C-Field
Manufacturer ID
M-Field
A-Field
CI-Field
14 04 00 19 03
07
Data-Field
02
00
Description
Short-Header
AD
02
00
00
00
00
RSSI
36 30
BF
Value
Meaning
0xFF
Frame start-up
0x19
Data field length
0x44
SEND/NO REPLY
0x4606
Manufacturer's number: 0x4606 = ARF
Data-Field
2F 2F
01
13
00