3.3. Connecting the meters to the screw terminals

Once the nut and the compression gland seal have been installed, the meter cables can be connected to the AMR PULSE'S screw terminal.
Please find details of each terminal below:
Note: a maximum of two meters of the same type can be used in parallel.
Please find a description of the terminals below:
Meter #1 pulse: white
Meter #1 GND: brown
Meter #1 fraud: green
Meter #2 fraud: green
Meter #2 GND: brown
Meter #2 pulse: white
Wiring for the 1 meter, 2 wire version
Procedure:
Connect the white wire to terminal IMP1
Connect the brown wire to terminal GND
Link the exposed end of the green fraud wire (FRD1) to the GND of the sensor
Note: always connect the green (fraud) wire last!
Wiring for the 2 meter, 3 wire version
Wire in the same manner as for 1 meter versions: symmetry as compared with the case's axis.
Procedure:
Connect the white wire to terminal IMP1
Connect the brown wire to terminal GND
Connect the green wire to terminal FRD1
Connect the white wire to terminal IMP2
Connect the brown wire to terminal GND
Connect the green wire to terminal FRD2
Close the case and tighten the screws
Note: always connect the green (fraud) wire last!
IMP1
GND
FRD1
FRD2
GND
IMP2