Owner's Manual
debris. Take care not to damage any interior components. See Fig. B.
1. Unplug unit.
2. Remove housing, locate coils and allow coils to dry if wet.
3. Vacuum both sides of the coils until clean, being careful not to let the nozzle
touch the fins; as that may cause damage by bending them.
Check catch basin tray. Clean when dirt and debris are present.
1. Wipe clean with a rag.
Check drain hose.
1. Look for obstructions. Disconnect and clear any debris present.
2. Reattach drain hose.
ANNUALLY
Have the pump system inspected by your local authorized distributor.
1.10 Troubleshooting
FAULT
Unit does not
operate
Unit operating, but
room not dry
Unit continuously
in defrost mode
DrizAir 1200 Owner's Manual108998K
CAUSE
Unit not switched
on.
No power to
machine.
Not enough time to
dry.
Poor air movement
in room.
Excessive moist air
infiltration.
Room temperature
too low
SOLUTION
Switch unit on.
Plug in unit; check power cord
connection at wall outlet.
Allow more time for drying.
Increase air movement with air
movers.
Reduce infiltration.
Increase room temperature.
© 2023 Legend Brands, Inc.
14