rough framing
EN
single-sided recessed
WARNING
!
When using DHM, power and A/V cables being run through the enclosure must maintain a 7" clearance from the top of
the collector box and a 3.5" clearance from all other ducting and venting components. Conduit is also required, but high
temperature conduit is recommended.
note:
Finish framing must be built
after appliance has been placed
in its final position and venting
connected.
The Linear series requires a
minimum enclosure height,
as illustrated (dimension L),
measured from the bottom of
the appliance. For temperature
requirements, this area must be
left unobstructed. Some venting
configurations that require more
vertical rise will require a larger
enclosure to provide minimum
vertical clearance between vent
pipes and combustibles.
minimum framing
Ref
38" models
K
E
F
53 13/16" (136.7cm) 65 13/16" (167.2cm) 77 13/16" (197.6cm) 89 13/16" (228.1cm)
J
L
Q
R
M
* Opening must be centered in enclosure on appliance. Dimensions represent finished sizes and where applicable should be
adjusted to include finish material thickness.
8
W415-2968 / C / 03.29.23
Q
L
M
J
50" models
39 15/16" (101.4cm)
18" for single-sided | 16 3 1/6" for see-thru
Optional - Appliance does not need to be elevated above floor
84" (213.4cm)
39 1/4"
3 3/4" (78mm)
R
K
E
F
62" models
91" (231.1cm)
4 1/8"
63 3/4"
3/4" plywood
74" models