WARNING
!
Enclosure top MUST be installed 3" from discharge opening. Enclosure ceiling required if the discharge
opening is more than 3" from the enclosure top.
All discharge air opening(s) / grill(s)
FLUSH - front discharge (side view)
Flush - front discharge
3" min.
(ceiling)
3" max.
4 1/8"
6" min.
Wall
mounted
object
(picture
frame,
appliance,
etc.)
SIDE VIEW
TV RECESS - front discharge (side view)
TV recess - front discharge
3" min.
(ceiling)
3" max.
4 1/8"
6" min.
SIDE VIEW
Horizontal duct sections: A minimum clearance of 3" (76mm) on the top and 1" (51mm) on the sides and
bottom all around the ducting on all horizontal runs to combustibles is required.
Vertical duct sections: A minimum of 1" (25mm) all around the ducting on all vertical runs to combustibles is
required.
DUCTED HEAT MANAGEMENT DISCHARGE OPENING IS HOT WHEN APPLIANCE IS OPERATING!
Front discharge opening must be located out of reach of the user. Discharge opening must not be restricted by furnishings or decor.
Discharge opening opening is required to be centered with the appliance.
MUST be installed 4' from combustibles.
ceiling
(enclosure)
L
ceiling
(enclosure)
L
5.0 finish framing
FLUSH - side discharge (front view)
Flush / TV recess - side discharge
3" min.
3" max.
(ceiling)
(enclosure)
6 3/4"
6" min.
Wall
mounted
object
(picture
frame,
appliance,
etc.)
FRONT VIEW
IMPORTANT:
Appliance enclosure depth may need to be
increased for TV recess (side discharge)
applications.
finish framing
ceiling
L
W415-2968 / C / 03.29.23
EN
15