Wet Vacuum Cleaning - Dirt Devil Royal M3310 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2 Use

2.3 Wet vacuum cleaning

WARNING:
Danger of injury! The same safety instructions that are specified under
ZChapter 2.2, "Dry vacuum cleaning" apply. In addition the safety
instructions listed below apply only for wet vacuum cleaning.
ATTENTION:
Upon delivery both filters are mounted. Ensure that both filters are
mounted and undamaged for both dry vacuuming and wet vacu-
uming. If you are unsure, check this by proceeding as shown (Fig. 8,
Fig. 9, Fig. 10).
8
a
9
NOTE:
When you are finished with wet vacuum cleaning, allow the appliance to
run for 30 seconds longer so that any water in the hose can be trans-
ported into the tank.
ATTENTION:
For reasons of cleanliness and hygiene, we recommend that you empty
the dirt tank (ZChapter 3.1, "Emptying the dirt tank") and clean the cen-
tral lamellae filter (ZChapter 3.3, "Cleaning the filter sleeve and central
lamellae filter") after every wet vacuum cleaning task, and then let the
appliance dry.
12
12
b
WARNING:
Danger of injury! When cleaning wet, smooth surfaces there is an
increased risk of slipping and falling. Pay attention and proceed with
care. Wear non-slip shoes. It is best to walk only on surfaces you have
already vacuumed.
ATTENTION:
Only operate appliance when it is standing vertically or held vertically.
Otherwise wastewater can run into the motor. In addition wastewater
can escape from the appliance.
10
a
11
NOTE:
The flat nozzle (Fig. 11/a) is only suitable for wet vacuum cleaning. The
wet and dry parquet nozzles (Fig. 11/a) can be used for both wet and
dry vacuum cleaning.
The two small accessory nozzles (Fig. 5) have been developed for dry
vacuum cleaning.
NOTE:
Clean the nozzle used immediately after wet vacuum cleaning. Particu-
larly if you are using the wet and dry parquet nozzle, if you want to use it
for dry vacuum cleaning as well.
NOTE:
You can vacuum up a maximum of approx. 4 litres of liquid (Fig. 12),
before the integrated float seals the suction channel, to prevent a short
circuit. When the suction channel is sealed the appliance will make a
significantly higher pitched and louder noise. Liquid will no longer be
displaced.
If the integrated float block the suction channel:
1. Switch the appliance off and pull the plug out of the socket.
2. Allow the residual water to run out of the hose and into the dirt tank,
by lifting the hose until the water has run out of it.
3. Empty the dirt tank, ZChapter 3.1, "Emptying the dirt tank".
4. You can immediately switch the emptied and completely assembled
appliance back on.
b