Télécharger Imprimer la page

Generac XT Serie Manuel Du Propriétaire page 14

Publicité

Les langues disponibles

Les langues disponibles

Radio
*Refrigerator
Slow Cooker
*Submersible Pump (1-1/2 HP)
*Submersible Pump (1 HP)
*Submersible Pump (1/2 HP)
*Sump Pump
*Table Saw (10")
Television
Toaster
Weed Trimmer
* Allow 3 times the listed watts for starting these
devices.
Transporting/Tipping of the Unit
Do not store or transport the unit at an angle
greater than 15 degrees.
Starting Pull Start Engines
Recoil Hazard. Recoil could retract unexpectedly.
Kickback could result in death or serious injury.
Equipment and property damage. Disconnect electrical
loads prior to starting or stopping unit. Failure to do so
could result in equipment and property damage.
1. Unplug all electrical loads from the unit's
receptacles before starting engine.
2. Place generator on a level surface.
3. Rotate the fuel shut-off valve (A) counter-
clockwise to the ON (open) position. See
Figure
3-2.
4. Switch engine OFF/RUN/START switch to
RUN. See
Table 1: Generator Compo-
nents.
.
ON
OFF
Figure 3-2. Fuel Shut-off Valve
5. Slide engine choke lever (B) to Full
CHOKE position (left). See
12
50 to 200
2800
2000
1500
800 to 1050
1750 to 2000
200 to 500
1000 to 1650
WARNING
CAUTION
A
Figure
700
200
6. Firmly grasp recoil handle and pull slowly
500
until increased resistance is felt. Pull rap-
idly up and away.
7. When engine starts, move choke lever to
1/2 CHOKE position until engine runs
smoothly, then fully into OPEN (right) posi-
tion. If engine falters, move choke lever
back to 1/2-CHOKE position until engine
runs smoothly, then to OPEN (right) posi-
tion.
NOTE: If engine fires, but does not continue to
run, move choke lever to Full CHOKE (left)
and repeat starting instructions.
IMPORTANT NOTE: Do not overload gener-
ator or individual panel receptacles. These
outlets are overload protected with push-
to-reset circuit breakers. If amperage rat-
(000183)
ing of any circuit breaker is exceeded, that
breaker opens and electrical output to that
receptacle is lost. Read
Limits
Starting Electric Start Engines
(000136)
Equipment and property damage. Disconnect electrical
loads prior to starting or stopping unit. Failure to do so
could result in equipment and property damage.
1. Unplug all electrical loads from the unit's
receptacles before starting the engine.
2. Place generator on a level surface.
3. Rotate the fuel shut-off valve (A) counter-
clockwise to the ON (open) position. See
Figure
4. Slide engine choke lever (B) to Full
CHOKE position (left). See
5. Press and hold OFF/RUN/START switch
in the START position. When engine
starts, release the switch to the RUN posi-
tion.
6. When engine starts, move choke lever to
1/2 CHOKE position until engine runs
smoothly, then fully into OPEN (right) posi-
tion. If engine falters, move choke lever
back to 1/2-CHOKE position until engine
000208
runs smoothly, then to OPEN (right) posi-
tion.
3-3.
B
Figure 3-3. Choke Lever
carefully.
CAUTION
3-2.
Owner's Manual for Portable Generator
000209
.
Know Generator
(000136)
Figure
3-3.

Publicité

loading

Ce manuel est également adapté pour:

004538004535