7.2.4. Sensor specific adjustable parameters
Parameter Name
Selection of local/remote
adjustment
Trimmer value
Process data configuration
Analogue value
Switching Output 1
Switching Output 2
Switching Signal Channel 1
Switching Signal Channel 2
Dust alarm 1
Dust alarm 2
Temperaturer alarm
Short-circuit
Sensor Application pre-set
Temperature Alarm Threshold
High Threshold
Low Threshold
Safe ON/OFF Limits
SSC 1 - Safe limit
SSC 2 - Safe limit
Event Configuration
Maintenance (0x8C30)
Temperature fault event
(0x4000)
Temperature over-run
(0x4210)
Temperature under-run
(0x4220)
Short circuit (0x7710)
Quality of Teach
Quality of Run
Filter scaler
LED indication
30
Rev.00 - 06.2018 | CA18/CA30 Capacitve sensors with IO-Link interface | © 2018 | CARLO GAVAZZI Industri
Index Dec
Access
(Hex)
68 (0x44)
RW
69 (0x45)
RO
70 (0x46)
RW
1 (0x01)
RW
1 = Analogue value Active
2(0x02)
RW
1 = Switching Output 1 Active
3 (0x03)
RW
1 = Switching Output 2 Active
4 (0x04)
RW
5 (0x05)
RW
6 (0x06)
RW
7 (0x07)
RW
8 (0x08)
RW
9 (0x09)
RW
71 (0x47)
R/W
72 (0x48)
R/W
1 (0x01)
R/W
2 (0x02)
R/W
73 (0x49)
R/W
1 (0x01)
R/W
2 x standard hysteresis
2(0x02)
R/W
2 x standard hysteresis
74 (0x4A)
R/W
1 (0x01)
R/W
2 (0x02)
R/W
0 = Temperature over-run
3 (0x03)
R/W
Warning event - Inactive
0 = Temperature under-run
4 (0x04)
R/W
Warning event - Inactive
5 (0x05)
R/W
75 (0x4B)
RO
76 (0x4D)
RO
77 (0x4D)
R/W
78 (0x4E)
R/W
1 = LED indication Active
Default value
1 = Trimmer input
0 = Analogue value Inactive
1 = Analogue value Active
0 = Switching Output 1 Inactive
1 = Switching Output 1 Active
0 = Switching Output 2 Inactive
1 = Switching Output 2 Active
0 = SSC1 Inactive
0 = SSC2 Inactive
0 = DA1 Inactive
0 = DA2 Inactive
0 = TA Inactive
0 = SC Inactive
0 = Full scale range
120
- 30
0 = Maintenance
0 = Notification event Inactive
Notification - Inactive
1 = Notification event Active
0 = Temperature fault
Error event - Inactive
0 = Warning event Inactive
1 = Warning event Active
0 = Warning event Inactive
1 = Warning event Active
0 = Short circuit
Error event - Inactive
-
-
1
0 = LED indication Inactive
1 = LED indication Active
Data range
Data Type
0 = Disabled
1 = Trimmer input
UintegerT
2 = Teach-by-wire
10 ... 10 000
RecordT
0 = SSC1 Inactive
1 = SSC1 Active
0 = SSC2 Inactive
1 = SSC2 Active
0 = DA1 Inactive
1 = DA1 Active
0 = DA2 Inactive
1 = DA2 Active
0 = TA Inactive
1 = TA Active
0 = SC Inactive
1 = SC Active
0 = Full scale range
1 = Liquid level
UintegerT
2 = Plastic pellets
RecordT
-50 to 150 [°C]
IntegerT
-50 to 150 [°C]
IntegerT
RecordT
0...100
UintegerT
0...100
UintegerT
RecordT
0 = Error event Inactive
1 = Error event Active
0 = Error event Inactive
1 = Error event Active
0...255
UintegerT
0...255
UintegerT
1...255
UintegerT
BooleanT
Length
8 bit
16 bit
8 bit
30 bit
16 bit
16 bit
16 bit
8 bit
8 bit
16 bit
8 bit
8 bit
8 bit
8 bit

Publicité