Télécharger Imprimer la page

CARLO GAVAZZI CA18 Manuel D'instructions page 15

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 63
2.4.4.1.5. One shot leading edge
Each time a target is detected in front of the sensor the switching output generates a pulse of
constant length on the leading edge of the detection. See figure below.
Presence of target
2.4.4.1.6. One shot trailing edge
Similar in function to the one shot leading edge mode, but in this mode the switching output is
changed on the trailing edge of the activation like shown in the figure below.
Presence of target
2.4.4.1.7. Timer scale
Parameter defines if the delay specified in the Timer delay should be in milliseconds, seconds or
minutes
2.4.4.1.8. Timer Value
Parameter defines the actual duration of the delay. The delay can be set to any integer value
between 1 and 32 767
Rev.00 - 06.2018 | CA18/CA30 Capacitve sensors with IO-Link interface | © 2018 | CARLO GAVAZZI Industri
Example with normally open output
Example with normally open output
15

Publicité

loading

Ce manuel est également adapté pour:

Ca30