Télécharger Imprimer la page

CARLO GAVAZZI CA18 Manuel D'instructions page 16

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 63
5
Sensor front
S.P., Two P.
1. SSC1
Window,
Adj. Hyst.
S.P., Two P.
2. SSC2
Window,
Adj. Hyst.
3. Dust 1
4. Dust 2
5. Temp
6. EXT-Input
2.4.5. Output Inverter
This function allows the user to invert the operation of the switching output between Normally Open
and Normally Closed.
RECOMMENDED FUNCTION!
The recommended function is found in the parameters under 64 (0x40) sub index 8 (0x08) for SO1
and 65 (0x40) sub index 8 (0x08) for SO2 does not have any negative influence on the Logic
functions or the timer functions of the sensor as it is added after those functions.
CAUTION!
The Switching logic function found under 61 (0x3D) sub index 1 (0x01) for SSC1 and 63 (0x3D) sub
index 1 (0x01) for SSC2 is not recommended used as they will have a negative influence on the logic
or timer functions e.g. using this function will turn an ON delay into an Off delay as it is added for
the SSC1 and SSC2 and not only for the SO1 and SO2.
6
Sensor front
S.P., Two P.
1. SSC1
Window,
Adj. Hyst.
S.P., Two P.
2. SSC2
Window,
Adj. Hyst.
3. Dust 1
4. Dust 2
5. Temp
6. EXT-Input
2.4.6. Output stage mode
In this function block the user can select if the switching outputs should operate as:
SO1: Disabled, NPN, PNP or Push-Pull configuration.
SO2: Disabled, NPN, PNP, Push-Pull , External input (Active high/Pull-down), External input
(Active low/pull up) or External Teach input.
16
Rev.00 - 06.2018 | CA18/CA30 Capacitve sensors with IO-Link interface | © 2018 | CARLO GAVAZZI Industri
Selector
Logic
A
A
A - B
B
One of
AND, OR,
1 to 6
XOR, S-R
divider
Selector
Logic
B
A - B
One of
AND, OR,
A
XOR, S-R
1 to 6
B
divider
Selector
Logic
A
A
A - B
B
One of
AND, OR,
1 to 6
XOR, S-R
divider
Selector
Logic
B
A - B
One of
AND, OR,
A
XOR, S-R
1 to 6
B
divider
Time
Output
delay
inverter
ON, OFF
N.O., N.C.
One-shot
Time
Output
delay
inverter
ON, OFF
N.O., N.C.
One-shot
Time
Output
delay
inverter
Out 1
ON, OFF
N.O., N.C.
One-shot
Time
Output
delay
inverter
Out 2
ON, OFF
N.O., N.C.
One-shot
Sensor
output
Out 1
Out 1
NPN, PNP,
Push-Pull
Sensor
output
Out 2
Out 2
NPN, PNP,
EXT-
Push-Pull
Input
EXT-Input
Sensor
output
Out 1
NPN, PNP,
Push-Pull
Sensor
output
Out 2
NPN, PNP,
EXT-
Push-Pull
Input
EXT-Input

Publicité

loading

Ce manuel est également adapté pour:

Ca30