Télécharger Imprimer la page

CEMO UNI-Tank 750 Notice De Montage Et D'utilisation page 7

Publicité

CEMO UNI-Tank / MULTI-Tank 750 l
/1000 l
Tank documents and technical information,
Approval No.: Z-40.21-288
1.
Approval „OPERATOR EXCERPT" page
2. Transport, installation and
operating instructions
3. Inspection declaration
Productinformation
Important documents for the operator!
Please keep in a safe place!
(Documents are to be presented during inspec-
tions of the tank system.)
1. National Technical Approval
Translation of the original German
language version; not reviewed by the
Deutsches Institut für Bautechnik
[German Institute for Structural
Engineering]
General technical
approval/
General design
certification
Number:
Z-40.21-288
Applicant:
CEMO GmbH
In den Backenländern 5
71384 Weinstadt
Subject of this decision:
Blown polyethylene (PE-HD) containers with
integrated sheet steel collection container
750 l and 1000 l
Type: UNI Tank 750/1000
General technical approval is hereby granted for the above-mentioned item, which forms the subject
of this decision.
This decision comprises nine pages and five annexes made up of 17 pages.
A mark of conformity (PA-VI 321.135) was issued for the first time for the item on 13 March 1989.
Z12991.20
7-9
page
10
page
10
page
30
Approval body for building products and designs
Test authority for structural engineering
A public law institution jointly established by the German
Federal Government and the federal states
Member of the EOTA, UEAtc and WFTAO
Date:
Reference:
14/04/2020
II 27-1.40.21-24/20
Period of validity
from:
14 April 2020
to:
14 April 2025
1.40.21-24/20
General technical approval/
General design certification
No. Z-40.21-288
I
GENERAL PROVISIONS
1
This decision shall serve as verification of the usability or applicability of the item forming the
subject of this decision in accordance with the State building codes [Landesbauordnungen].
2
This decision is not intended to replace the permits, approvals and certifications required by law
for the execution of construction projects.
3
This decision is granted without prejudice to the rights of third parties, particularly private industrial
property rights.
4
Copies of this decision are to be provided to the user of the item forming the subject of this decision
without prejudice to any more detailed provisions included in the "Special provisions". In addition,
the user of the item forming the subject of this decision must be made aware of the fact that this
decision must be made available at the location in which the item is to be used or applied. Copies
must also be made available to the relevant authorities upon request.
5
This decision may only be duplicated in full. Extracts may only be published with the consent of
the Deutsches Institut für Bautechnik [German Institute for Structural Engineering]. Text and
images used in promotional literature must not contradict this decision; translations must include
the note: "Translation of the original German language version not reviewed by the Deutsches
Institut für Bautechnik".
6
This decision may be revoked. The provisions may subsequently be supplemented and amended,
particularly where this is required on the basis of new technical developments.
7
This decision has been made on the basis of the information and documents provided by the
applicant. Any changes made to such information and documents shall not be covered by this
decision and must therefore be reported to the Deutsches Institut für Bautechnik without delay.
8
The general technical approval included in this decision shall also serve as a general design
certification.
Z12991.20
General technical approval/
General design certification
No. Z-40.21-288
II
SPECIAL PROVISIONS
1
Item forming the subject of this decision and scope of use/application
(1) This decision concerns factory-produced containers in accordance with Annex 1, consisting of
a blow-moulded inner container made of polyethylene (PE-HD) and an outer container (collection
container) made of galvanised sheet steel. The containers are manufactured with a capacity of
750 l or 1000 l. There are four nozzles attached to the top of the containers to attach equipment
for filling, ventilation, protection against overfilling, emptying and, if applicable, level control. The
containers are placed on steel base frames. The gap (between the inner container and the
collection container) is equipped with a leak probe to detect any leaks that may occur.
(2) The containers may only be used as individual containers in rooms within buildings, but must
not be used in Zone 0 or 1 which are potentially explosive areas. When used in areas prone to
flooding, the containers must be positioned in such a way that the floodwater cannot reach them.
(3) The containers may be used at temperatures of the stored liquids of 30°C for stationary,
pressureless storage of the water-polluting liquids as listed below (although brief periods during
which the temperature exceeds this by 10 K (e.g. due to the higher temperature of the stored
liquids during filling) are permissible):
1. Fuel oil EL as described in DIN 51603-1
1
;
2. Fuel oil DIN 51603 - 6 EL A Bio 5 to Bio 15 as described in DIN SPEC 51603-6
addition of FAME in accordance with DIN EN 14214
components;
3. Diesel fuel as described in DIN EN 590
;
4
4. Fatty acid methyl esters as described in DIN EN 14214
5. Lubricating, hydraulic or Q heat transfer oils, blended or pure, flash point > 55°C;
6. Lubricating, hydraulic or Q heat transfer oils, used, flash point > 55°C; the operator must be
able to provide evidence of the origin and the flash point;
7. Plant-based oils such as cotton seed, olive, rapeseed, castor or wheat germ oil in any
concentration, which are not used as food or in the manufacture of food;
8. Photochemicals (commercially available), in use concentration (new and used) with a max.
density of 1.15 g/cm
3
; only in containers whose metal parts have an additional protective
coating.
(4) Mixing of the liquids being stored is not permissible.
(5) This decision has been granted without prejudice to the provisions and the testing and approval
requirements set out in other areas of law.
(6) This decision takes account of the requirements for the item forming the subject of this decision
under water law. According to Section 63(4)(2) and (3) of the German Federal Water Act
[Wasserhaushaltsgesetz, WHG]
5
the item forming the subject of this decision has therefore been
deemed suitable under water law.
(7) The period of validity of this decision (see page 1) relates to its application for the installation
or positioning of the item forming the subject of this decision and not to its application for the
subsequent use of that item.
1
DIN 51603-1: 2017-03
Liquid fuels - fuel oils - Part 1: Fuel oil EL Minimum requirements
2
DIN SPEC 51603-6: 2017-03
Liquid fuels - fuel oils - Part 6: Fuel oil EL A, Minimum requirements
3
DIN EN 14214: 2019-05
Liquid petroleum products - Fatty acid methyl esters (FAME) for use in diesel engines and heating
applications - Requirements and test methods; German version EN 14214:2012+A2:2019
4
DIN EN 590: 2017-10
Automotive fuels - Diesel - Requirements and test methods
5
German Federal Water Act of 31 July 2009 (Federal Law Gazette I p. 2585), last amended by Article 1 of the Law of 18 July 2017
(Federal Law Gazette I p. 2771)
Z12991.20
GB
Page 2 of 9 | 14. April 2020
1.40.21-24/20
Page 3 of 9 | 14. April 2020
2
with the
, without any additional alternative
3
(biodiesel);
3
1.40.21-24/20
7