Safety Warnings - Astralpool 54092 Manuel D'installation Et D'entretien

Projecteur immerge par56 a leds
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 6
7. CHANGE OF LAMP:
To remove the floodlamp to the edge of the swimming pool (Fig. 5) loosen the two DIN 966 M5 x 40 screws (no. 1) until the fastening dog
yields sufficiently so that the floodlamp unit can be separated from the housing.
To remove the lamp, unscrew the 3 nuts (no. 15) which secure the decorative ring (no. 13) to the base of the floodlamp (no. 2).
Remove the lamp (no. 7) from the inside of the base of the floodlamp and disconnect the two terminals, loosening the two screws which secure
them to the lamp. (Fig. 6).
Change the lamp and assemble the Floodlamp, in the opposite order described in point 4 of assembly, taking special care to:
Connect the cable terminals to the lamp, using the 2 screws supplied with the lamp (Fig. 6).
Fully centre the Ø90x10 O-ring (no. 8) in its seat.
Firmly tighten the screws.
Attention:
Before any handling ensure that there is NO voltage supplied to the floodlamp.
The new lamp should have the same characteristics as that supplied with the floodlamp, of led PAR56 , 12 V.
In order to ensure full watertightness, clean the seat of the O-ring (no. 8) for the lamp or replace the O-ring if you observe any notches or
permanent damage.
THE HOLES AT THE BACK OF THE LAMP SHOULD BE LEFT FREE WHEN ASSEMBLING THE PROJECTOR, SO THAT WATER
8. START-UP:
The components listed below are optional.
Cable duct hose, code 28138: This hose fits in with the gland seal body, and thus ensures watertightness. Facilitates maintenance of electric
cable for installation. Protects the electric cable from blows and grazing.

9. SAFETY WARNINGS:

The persons who are in charge of assembly should have the required qualifications for this type of work.
If the end cable of this light fitting is damaged, it should only be replaced by the manufacturer, its technical service or by a
similarly qualified person, to avoid any danger.
Avoid making contact with the electric voltage.
Comply with the current standards regarding accident prevention.
In this regard, the IEC 364-7-702 standards must be observed. WIRING IN BUILDINGS. SPECIAL WIRING. SWIMMING POOLS.
Any operation related to the maintenance or replacement of parts should be performed with the floodlamp disconnected from the
electric power system.
Do not handle with wet feet.
The lamp is designed TO BE USED ONLY SUBMERGED IN WATER and TO OPERATE ONLY WITH A SAFETY TRANSFORMER.
The manufacturer is not responsible in any circumstances for assembly, installation or start-up of any electric components which
have been inserted or handled at locations other than its own premises.
The projector is equipped with a 2x1.5 section cable according to the power of the lamp supplied. If the lamp is changed, the
cable section should be recalculated and changed if necessary.
A T T E N T I O N
CAN FLOW INSIDE FOR OPTIMUM PERFORMANCE OF THE LAMP.
5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

54093 540945409554097540985409954100

Table des Matières