Remove the external packaging, remove the protective plastic film from the surface of the appliance and clean 
the external parts of the  appliance with a cleaner  designed for this purpose.  Do  not use steel  wool or any 
coarse agents, which could irreparably damage the surface of the appliance. 
 
IMPORTANT
This unit can be installed as either built‐in or free‐standing unit. For built‐in installation, certain clearances are 
necessary for optimal operation. In this case, allow 3/16" on both sides, 2" at the rear and 1/16" at the top to 
ensure proper ventilation. Take care that the air vent at the front of the appliance is never covered or blocked 
in any way. 
 
 
BEFORE INSTALLATING OF YOUR APPLIANCE
The   placement   of   the   appliance   must   meet   the   requirements   in   the   section   operating 
conditions  and  must  include  a  stable  floor  with  a  load‐bearing  capacity  corresponding  to  the 
weight of the appliance. 
Level the appliance using the adjustable feet. Ensure there is a gap between the bottom edge 
of the appliance and the ground, so that there is sufficient circulation of air. This will ensure the 
optimal performance of the cooling system. 
Use the appliance only for the purposes for which it has been designed. 
The  appliance  must  be  located  on  a  rigid  and  even  surface.  In  this  way  you  will  ensure  free 
circulation of the coolant and effective operation of your appliance. 
If possible, place the appliance in a cool, well ventilated and dry room. 
Do not locate the appliance in direct sunlight or in a room with a high ambient temperature, or 
in  the  vicinity  of  any  sources  of  direct  heat,  such  as a  radiator  or oven.  This  would  cause  the 
compressor to work harder, resulting in a substantially higher power consumption level. 
 
ELECTRICAL REQUIREMENTS
A 115 Volt / 60 Hz grounded electrical supply equipped with a 15 or 20 amp fuse or circuit breaker is required. 
It is recommended that a separate  circuit serving only your appliance be  provided. Use outlets that cannot 
be turned off by a switch or pull chain. Connect this appliance to a 3‐prong power supply outlet that has a 
ground terminal. If you only have a 2‐prong outlet, have it replaced by a qualified technician with an  outlet 
that  meets  the  local  codes.  DO  NOT  USE  AN  EXTENSION  CORD.  Required  nominal  voltage  and frequency 
are indicated on the rating plate. The connection to the power supply and grounding has to be made according 
to current local standards and regulations. 
 
 
BUILT-IN INSTALLATION DIMENSIONS (MM/IN)
 
If your appliance is to be built‐in, follow the diagram and chart below for appropriate dimensions. 
 
 
 
 
 
 
Chart 
610mm (24") 
610mm (24") 
883mm (34 ¾") 
152mm (6") 
51mm (2") 