TIMER OPERATION
For SRE 300
For SRE 4600
TIMER OPERATION
Timer operation is available only after the current time is entered.
*When < TIMER CONTROL > key is pressed, buzzer sounds as the current time is displayed.
EX: To program AM. 6:35
1.
Press < ON > key.
Operation lamp lits.
*This step is not necessary while the heater is already in operation.
2.
Press < TIMER CONTROL > key.
Operation stops and the operation lamp goes off.
Timer operation lamp lits, and digital indicator shows restarting time 6:00.
3.
Enter restarting time
Time indication changes by minute at each pressing of time key.
Press the key for a few seconds and the figure will continue to change.
After the minutes reaches 10, figure changes by every ten minutes.
Press the key one at a time for minute adjustment.
4.
Press <TIMING> key, and program the working duration.
[--h] indicates the combustion goes on without stop, [10h] indicates 10 hours, [9h] does 9
hours, ... and [1h] does 1 hour of combustion.
5.
Timer programming is now completed.
*Confirm that the timer lamp is lit.
*Digital indicator shows the mode selected.
The Unit restarts at the programmed time.
NOTES:
The stating hour of the TIMER can be modified when you want. You must only press on the switch
MODE and adjust the hour with the button + and –.
TIMING