IGNITION
For SRE 300
TIMING
Check the state of the flame through window.
Normal flames:
Blue-colour flames with partially red flames tips.
At the minimum power heating burner will turn red without blue flames.
Abnormal flame:
Red-colour flames
[Causes]
Lack of fresh air.
Dust on the intake filter.
Improper air intake because of the heater location too close to wall or drapes.
Recoveries]
Ventilate the room to get fresh air.
Remove dust on the intake filter.
Relocate the heater to proper places.
Unstable flames
[Cause]
Stuck fuel flow caused by dirties along pumping system.
[Recovery]
Stop the operation and consult with local distributor.
Contact your local distributor or your nearest customer service agent if any other extraordinary
flame state is observed.
NOTES!
The heater may not ignite at once when using it for the first time.
<ON> key flashes red, indicating "E1". Press <OFF> key first, then <ON> key.
The Unit will not start when <ON> key is pressed for 5 seconds or longer.
<ON> key flashes red, indicating "E0". Press <OFF> key first, then <ON> key.
It is quite normal that when the Unit is being lit, it makes a low sound of ignition.
Some burning smell may be come out at ignition or extinguishment. Ventilate the room atmos-
phere.
For SRE 4600
Ignition
Press <ON> key.
Operation lamp (same as <ON> key) will lit red.
The lamp is red under any of the heat power modes.
Preheating begins with "05" shown on the digital indicator.
Indication continues to "04""03""02""01" and about 2 minutes lat-
er combustion begins and warm air will be generated.
<ODOR-FREE> lamp lits at the time of starting then cuts it self.