5.1 Load-shedding
If you have chosen not to use the Cyclope OptiPower
use a load-shedding pilot wire.
In this case, connect the black wire to the load-shedding pilot wire.
The pilot wire 'stop' position overrides the system and switches the Cyclope
thermostat to 'stop' position whatever the status of the thermostat.
(See electrical connection instructions on p.4).
Control the thermostat using a programming base unit able to issue the
instructions given in the table below.
Connect the base unit to the thermostat using a pilot wire.
Check that the command signal corresponds to the desired operating mode.
Mode
COMFORT
ECONOMY
ECONOMY 1
ECONOMY 2
FROST-PROTECTION
OFF
6.1 Technical characteristics of the thermostat
Power supply
Heating power
Insulation category
Protection category
Shock resistance
Operating temperature
Storage temperature
Operating humidity levels
Temperature control
Temperature selection range
Maximum error I selected temperature
NF (French Norms) Performance Category C
24
CYCLOPE
®
ELECTRONIC THERMOSTATS
User instructions
Command description
No signal
Alternating
No current for 5 minutes.
Alternating for 3 seconds.
No current for 5 minutes.
Alternating for 7 seconds.
Negative half-wave
Positive half-wave
230 V 50 Hz
2000 W maximum
II
IP24
IK10
0 ÷ 50°C
-20÷80°C
20÷95% without any condensation
Analogical using a knob
7 ÷ 30°C
0.5°C
function, then you can
Signal
®