■ ELECTRICAL WIRING
1- The radiator is "class II" with dual insulation
2- The radiator is not equipped with an earth wire and it is
strictly forbidden to connect it to the ground.
3- For thermostats equipped with a pilot wire to be connected
to programming systems, it is essential to get a correct
connection of the phase and neutral.
Colour code: (see picture 1) BROWN connection with the
phase/ GREY connection with the neutral/BLACK
connection with the pilot wire (if necessary).
RADIATOR CONNECTION
Programming
L
4- If the pilot wire is not connected, the wire tip must be
insulated.
5- ▲ The pilot wire direct connection to the power supply
(phase, neutral or earth) will destroy the thermostat.
CAUTION: Before any installation or operation on
the electrical circuit, please cut off the power
supply with the circuit breaker or with the main
circuit breaker and check if there is live wire.
18
.
Figure 1
L = Phase
system
Brown color
N
N = Neutral
FP
Grey color
FP = Pilote wire
Black color
■ STARTING
1- Check that the radiator is correctly supplied with electricity
then test the various functions of the thermostat and set
the temperature you want to get. For this operation, refer to
the Cyclope
®
electronic thermostat user's manual.
2- In case of faulty operation, please check that the radiator is
properly supplied with electricity.
If the radiator is properly supplied and if it does not work
correctly, please advise your installer or the manufacturer.
■ SAFETY INSTRUCTIONS
1- Do not dismount nor modify the radiator.
2- In order to avoid any risk of electrocution:
- Do not take apart the electronic thermostat
which has been assembled in the factory
- Do not introduce a metallic object into the thermostat
- The electrical cable integrated in the factory is not
replaceable; delivered in a standard length it should not
be extended, nor shortened.
DO NOT twist or jam the cable in the radiator wings behind it.
- If the cable is damaged, you risk very serious wounds
that could lead to death. After its replacement, if the
assembly was not carried out properly, you risk the same
wounds.
If the electric cable is damaged, it must be replaced by the
manufacturer, its after-sale service or by people of similar
qualification, in order to avoid any danger.
WARNING: in order to avoid overheating, do not to cover
the heating appliance. The heating appliance should not
be placed just below a socket-outlet.
3- This heating appliance is filled with an accurate quantity of
special fluid. Repairs requiring the opening of the fluid tank
should only be carried out by the manufacturer or his after
sale service which normally should be contacted in the
event of fluid leakage.
4- When the heating appliance is to be sent to the dump,
respect the regulations concerning the oil recycling.
Fluid residues will have to be recycled in a registered facility in
conformity with the local, regional or national regulations.
5- In case of failure or possible repairs, contact your supplier.