DIAGNOSIS
CLOSE

ADJUSTMENT 3%

ADJUSTMENT 3%
COMPLETE > 500 ml
COMPLETE ml
OPEN
©
©
DOSATRON INTERNATIONAL S.A.S. / 24
DOSATRON INTERNATIONAL S.A.S. / 60
Verification of the doser against the factory
data using a graduated test tube and the water
meter. In this sub-menu it is possible to exit
each screen using the empty arrow
Check that the suction pipe is primed
before starting each procedure "DIAGNOSIS".
Close the valve upstream of the Dosatron
to prepare for browsing in the diagnosis menu
After 10 secs a new screen appears
Set your doser manually to 3%
The red LED lights up as long as the dosing
value is not reached
When the doser is set to 3%, the value of
3% stops blinking and the following screen
appears
Position the suction pipe strainer with the
level detector pipe in the test tube
Fill the test tube to over 500 ml
Ensure that the doser suction pipe is
correctly filled before starting the automatic
diagnosis. The blinking of the word FILL
disappears and the following screen appears
Open the valve upstream of the doser
to operate the motor and the drain valve
downstream of the doser to generate a water
flowrate necessary for the diagnosis