C 320-360V is input to power module and power module switches power supply current according to rotation
position of magnet rotor. The switching order is as shown in Fig. 3-2.
At point E: U + is ON, V - is ON (circuit in Fig. 3-1)
          
At point F: U + is chopped (OFF), V - is ON (circuit in Fig. 3-4)
          
Upper arm
transistor
Lower arm
transistor
Upper arm transistor is controlled to ON/OFF by 3.2kHz chopper signal. Rotation speed of the compress is
proportional to duty ratio (ON time/ ON time + OFF time) of this chopper signal.
Time T in Fig. 3-2 shows the switching period, and relation with rotation speed (N) of the compressor is shown
by formula below;
N=60/2
          
Fig. 3-3 shows voltage waveform at each point shown in Fig. 3-1 and 3-4. First half of upper arm is chopper,
second half is ON, and first half of lower arm is chopper, second half is ON.
+
U transistor chopped
Voltage between
A
320-360V
Upper arm transistor
Current at
B
When power is supplied U +
(1)When U + transistor is ON: U + transistor
resistor
Point
(Fig. 3-1)
(2)When U + transistor is OFF: (by inductance of motor coil) U coil
diode
Point
(Fig. 3-4)
All manuals and user guides at all-guides.com
+
+
V
W
-
U
Fig. 3-2 Switching order of power module
1/T
×
Chopping period
T
Chopping period(313
sec.)
μ
ON
Fig. 3-3 Voltage waveform at each point
U - , because of that U + is chopped, current flows as shown below;
U coil
- 288 -
E F
+
U
-
-
V
W
T
-
transistor ON
U
V - transistor
V coil
V - transistor
V coil
+
V
Time
C current detection
Returm
loading