. Room Temperature Thermistor Circuit
ODEL RAD-25NH5, RAD-35NH5, RAK-18NH5, RAK-25NH5, RAK-35NH5, RAK-50NH5, RAI-25NH5, RAI-35NH5, RAI-50NH5
Fig. 5-1 shows the room temperature
thermistor circuit.
5V
Room temperature
thermistor
R305
C302
R301
A
0V
0V
Fig. 5-1
6. Heat exchanger temperature thermistor circuit
ODEL RAD-25NH5, RAD-35NH5, RAK-18NH5, RAK-25NH5, RAK-35NH5, RAK-50NH5, RAI-25NH5, RAI-35NH5, RAI-50NH5
5V
Heat exchanger
temperature thermistor
The circuit detects the indoor heat exchanger
temperature and controls the following.
(1) Preheation.
(2) Low-temperature defrosting during cooling
and dehumidifying operation.
(3) Detection of the reversing valve non-operation
or heat exchanger temperature thermistor open.
The voltage at depends on the heat exchanger
A
temperature as shown in Fig. 6-2