Proline Promag W 400
Spécifications tube de
mesure
Endress+Hauser
AWWA C207, Class D
DN
[in]
48
54
60
66
72
78
Variante de commande "Option capteur", Option CA
Option CA "IP66/67, Type 4X, entièrement soudé; protection anti-corrosion EN ISO 12944 C5-M"
ASME B16.5, Class 150
DN
[in]
1
1½
2
3
4
6
8
10
12
Diamètre nominal
EN (DIN)
[mm]
[in]
25
1
PN 40
32
–
PN 40
40
1 ½
PN 40
50
2
PN 40
65
–
PN 16
80
3
PN 16
100
4
PN 16
125
–
PN 16
150
6
PN 16
200
8
PN 10
250
10
PN 10
300
12
PN 10
350
14
PN 6
375
15
–
400
16
PN 6
Palier de pression
ASME
AS 2129
JIS
AWWA
AS 4087
Class 150
–
20K
–
–
20K
Class 150
–
20K
Class 150
Table E, PN 16
10K
–
–
10K
Class 150
Table E, PN 16
10K
Class 150
Table E, PN 16
10K
–
–
10K
Class 150
Table E, PN 16
10K
Class 150
Table E, PN 16
10K
Class 150
Table E, PN 16
10K
Class 150
Table E, PN 16
10K
Class 150
Table E, PN 16
–
PN 16
Class 150
Table E, PN 16
Poids
[lbs]
1 987
1 273
3 515
4 699
5 662
6 864
Poids
[lbs]
13
15,5
20
29
37
57
93
130
185
Diamètre intérieur tube de mesure
Ebonite
Polyuréthane
[mm]
[in]
[mm]
–
–
24
–
–
32
–
–
38
50
1,97
50
66
2,60
66
79
3,11
79
102
4,02
102
127
5,00
127
156
6,14
156
204
8,03
204
258
10,2
258
309
12,2
309
–
342
13,5
342
–
392
15,4
–
–
392
15,4
392
[in]
0,94
1,26
1,50
1,97
2,60
3,11
4,02
5,00
6,14
8,03
10,2
12,2
13,5
–
15,4
89