Prior to Initial Operation
The unit is set up in the desired location with the air out-
let side facing the room. Follow the safety instructions
when setting up the unit.
There must be a minimum of 20 cm between the
back of the unit and the wall.
After unpacking the unit, place it on
its transport wheels and let it stand
for a minimum of 5 min. before
switching it on.
5 MIN.
Place the unit securely on a level
and firm surface.
An uneven surface can cause vibra-
tions and disruptive noises.
Before plugging in the power cord,
make sure that the required current is
available!
230V / 1~, N, PE / 50 Hz.
If extension cords are necessary,
make absolutely sure that they are
sufficiently thick.
All extensions of the power cords
must be sufficiently thick and may
only be used if they are completely
extended.
Make sure that there is a plug for the
condensation drain and that it has
been securely placed.
Condensation
drain with plug
Water may leak out after the unit be-
comes operational.
Exhaust filter
Never operate the unit without the
Circulation filter
intake filter.
Without an air intake filter, the plate
fins of the evaporators become dirty
and the unit's performance is ad-
versely affected.
Make sure that people and objects,
such as plants in the room, are not
directly in the path of the expelled air.
Recommendations for optimum unit operation.
In case of direct sunlight, make sure
to close all curtains and blinds.
Keep doors and windows closed
during operation.
8
Expelling the warm air
During cooling mode, the unit generates warm air. This
air must be expelled from the room to retain the cooling
effect.
It is therefore necessary to insert the supplied exhaust
hose into the air outlet opening at the back of the unit.
Make sure that the deflector piece
from the top slides down into the
notches on the side until it clicks into
place.
To ensure that the unit operates ef-
fectively, do not place the flexible ex-
haust hose supplied at sharp angles
and make sure there are no kinks.
You may not extend the exhaust hose.
The air expelled from the unit contains a certain
amount of moisture. We therefore recommend ex-
pelling the air to the surroundings or the outside.
Different ways of expelling air
You can expel air from the building as follows:
1. With a flat nozzle.
The flat nozzle supplied can be
used in different ways.
It is possible to guide the flat nozzle
through the open window and se-
cure it firmly using straps and suc-
tion devices.
The flat nozzle can also be hung
through the partially opened win-
dow.
2. With a fixed connection to the ex-
haust hose (wall lead-through).
The hose supplied is firmly con-
nected to a wall lead-through.
Lead-through kits can be pur-
chased as accessories.
The exhaust hose must always be placed at an in-
cline in the direction the air is flowing!
In some circumstances, low pressure can occur in the
setup room when air is being expelled via a perma-
nently attached exhaust hose, e.g. as a result of closed
windows or doors. If the performance of the unit is ad-
versely affected as a result, make sure that the pressure is
corrected.