Description of Device
The RKL 290-350 air conditioner comes with an infra-
red remote control and an air outlet hose with a flat
nozzle.
Air directing
plate fins
Recessed
grip
Transport
wheels
Air filter
circulation
Air intake
circulation
Air filter exhaust
Air outlet hose
Air outlet exhaust
Condensation drain with
plug
Cable holder
Air intake exhaust
The unit's primary function is to air-condition rooms. It
also filters and dehumidifies the air, thus creating a
comfortable climate in the room.
In "Fan" mode, the unit can also be used to circulate air
with no cooling effect.
The units operates fully-automatically and offers a
range of other options thanks to its microprocessor con-
trol. For example, it can be automatically switched off
and on at a preset time via the timer function.
The unit is comfortably operated via the control panel
on the indoor unit or via the infrared remote control that
comes with it.
The unit has been designed for automatic, universal,
smooth air dehumidification. Its compact dimensions
make it easy to transport and set up in all rooms.
The unit meets the basic safety and health require-
ments found in the relevant EU regulations. It is safe
Air outlet
and easy to operate.
Control panel
Functional principle
The portable air conditioner cools the air in the room by
extracting the heat from it. The heat absorbed is ex-
IR receiver
pelled to the outside via the exhaust hose and the
cooled air is resupplied to the room where the unit is in
operation via a fan.
Condensation that accumulates drips from the evapora-
tor onto the hot condenser where it condenses and is
then transported via the air outlet hose to the outside.
Excess condensation drips from the condenser into a
collection tray and is resupplied to the condenser by
means of a rotating wheel with blades, where it evapo-
rates and is then expelled with the outgoing air current.
Cool circulating air in
the room
The environmentally-friendly refrigerant, R 407C, trans-
ports the absorbed heat within the closed-loop refriger-
ant cycle.
Operation
Prior to putting the unit into operation, ensure that all
safety instructions have been observed.
Please note that the unit operates most efficiently and
most comfortably when put into operation before the
hottest part of the day, e.g. the morning.
The selected target temperature should be 4 to 7°C be-
low the outside temperature. It should never be lower
because the room temperature would feel too cold
when coming from a non-air-conditioned room and peo-
ple may catch cold.
The selected target temperature does not affect the
performance of the unit! This means that when tem-
peratures in the room are high, it is not practical to ad-
just the unit to the lowest possible target temperature.
Fan for cir-
culation
Fan for out-
going air
Compressor
Evaporator
Circulation intake
from the room
Warm air expel-
led to the outsi-
de
Condenser
Expelled air intake
from the room
Refrigerant
cycle
5