1. General
In operation, drive converters, depending on their degree of
protection, may have live, uninsulated, and possibly also
moving or rotating parts, as well as hot surfaces.
In case of inadmissible removal of the required covers, of
improper use, wrong installation or maloperation, there is the
danger of serious personal injury and damage to property.
For further information, see documentation.
All
operations
serving
commissioninng as well as maintenance are to be carried out
by skilled technical personnel (Observe IEC 364 or CENELEC
HD 384 or DIN VDE 0100 and IEC 664 or DIN/VDE 0110 and
national accident prevention rules!).
For the purposes of these basic safety instructions, "skilled
technical personnel" means persons who are familiar with the
installation, mounting, commissioning and operation of the
product
and
have
the
qualifications
performance of their functions.
2. Intended use
Drive converters are components designed for inclusion in
electrical installations or machinery.
In case of installation in machinery, commissioning of the
drive converter (i.e. the starting of normal operation) is
prohibited until the machinery has been proved to conform to
the provisions of the directive 89/392/EEC (Machinery Safety
Directive - MSD). Account is to be taken of EN 60204.
Commissioning (i.e. the starting of normal opertion) is
admissible only where conformity with the EMC directive
(89/336/EEC) has been established.
The drive converters meet the requirements of the low-voltage
directive 73/23/EEC. They are subject to the harmonized
standards of the series DIN EN 50178/VDE 0160 in
conjunction with EN 60439-1/ VDE 0660, part 500, and EN
60146/ VDE 0558.
The technical data as well as information concerning the
supply conditions shall be taken from the rating plate and from
the documentation and shall be strictly observed.
3. Transport, storage
The instructions for transport, storage and proper use shall be
complied with.
The climatic conditions shall be in conformity with EN 50178.
Seite 4 von 13
Safety and operating instructions for
drive converters
in conformity with the low-voltage directive 73/23/EEC
transport,
installation
and
needed
for
the
4. Installation
The installation and cooling of the appliances shall be in
accordance
with
the
specifications
documentation.
The drive converters shall be protected
strains. In particular, no components must be bent or isolating
distances altered in the course of transportation or handling.
No contact shall be made with electronic components and
contacts.
Drive converters contain electrostatic sensitive components
which are liable to damage through improper use. Electric
components must not be mechanically damaged or destroyed
(potential health risks).
5. Electrical connection
When working on live drive converters, the applicable national
accident prevention rules (e.g. VBG 4) must be complied with.
The electrical installation shall be carried out in accordance
with the relevant requirements (e.g. cross-sectional areas of
conductors, fusing, PE connection). For further information,
see documentation.
Instructions for the installation in accordance with EMC
requirements, like screening, earthing, location of filters and
wiring, are contained in the drive converter documentation.
They must always be complied with, also for drive converters
bearing a CE marking. Observance of the limit values required
by EMC law is the responsibility of the manufacturer of the
installation or machine.
6. Operation
Installations which include drive converters shall be equipped
with additional control and protective devices in accordance
with the relevant applicable safety requirements, e.g. Act
respecting technical equipment, accident prevention rules etc.
Changes to the drive converters by means of the operating
software are admissible.
After disconnection of the drive converter from the voltage
supply, live appliance parts and power terminals must not be
touched
immediately
because
capacitors. In this respect, the corresponding signs and
markings on the drive converter must be respected.
During operation, all covers and doors shall be kept closed.
7. Maintenance and servicing
The manufacturer's documentation shall be followed.
KEEP SAFETY INSTRUCTIONS IN A SAFE PLACE!