Connection And Maintenance Of Ventilation; Technical Features; Allowed / Not Allowed Fuels - LA NORDICA INSERTO 70 L Instructions Pour L'installation, L'utilisation Et L'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Should the inflow of air be obtained by openings communicating with outside of nearby rooms, it is
necessary to avoid air intakes in connection with garages, kitchens, bathrooms, thermal units (see
Picture 14).
9.

CONNECTION AND MAINTENANCE OF VENTILATION

The control unit and the plant must be installed and connected by authorized personnel according to the
standards in force. (see chapter.1)
ATTENTION: the feeding cable must not be in contact with hot parts.
Our inserts are equipped with tangential fans suitable to improve the distribution of heat through the ventilation
exclusively of the installation room. (see chapter.6)
The lighting and the adjustment is carried out through the proper standard supplied control unit that has to be installed
far from any direct heat source. The kit is equipped with a thermostat (TM) that lets the fans start when the appliance
is properly heated, and stops them when it is partially cold.
If the control is switched on (pos.
temperature is achieved.
The selection of the kind of insert to be connected is in the control unit and has to be done by moving the small bridge
as shown hereafter (see chapter 21) before the INSERT starts to operate. This operation must be done without
electric energy!!
MANDATORY: cable
out of seeing!
Picture 15
For the connection of the OPTIONAL ventilation kit, please see chapter 21.
WARNING: The COMMAND must be connected to the mains with a differential line cut-off switch according to
the regulations in force. Correct operation of the command is assured only for the proper motor for
which it has been manufactured. Improper use relieves the manufacturer from each responsibility.

10. ALLOWED / NOT ALLOWED FUELS

Allowed fuels are logs. Use exclusively dry logs (max. content of water 20%). Maximum 2 or 3 logs should be loaded.
The pieces of wood should have a length of ca. 20-30 cm and a maximum circumference of 30-35 cm.
The not worked-out compressed logs must be used with care to avoid overheating that may damage the
appliance, since these have a high calorific value.
The wood used as fuel must have a humidity content lower than the 20% and must be stored in a dry place. Humid
wood tends to burn less easily, since it is necessary a greater quantity of energy to let the existing water evaporate.
Moreover, humid content involves the disadvantage that, when temperature decreases, the water condensates earlier
in the hearth and therefore in the stack causing a remarkable deposit of soot with following possible risk of fire of the
same.
Fresh wood contains about 60% of H
It is necessary to place this wood in a dry and ventilated place (for example under a roofing) for at least two years
before using it.
Besides others, it is not possible to burn: carbon, cuttings, waste of bark and panels, humid wood or wood
treated with paints, plastic materials; in this case, the warranty on the appliance becomes void.
Paper and cardboard must be used only to light the fire.
The combustion of waste is forbidden and would even damage the appliance and the flue, causing health damages
and claims by the neighborhood owing to the bad smell.
22
I
halfway speed – pos.
CONNECTION:
Connect the feeding cable of the switchboard with an
electronic bipolar switch respecting at least a 3 mm
distance between the contacts (power supply 230V~
50Hz, it is necessary to provide for the correct connection
to the grounding plant) please see chapter 21.
O, therefore it is not suitable to be burnt.
2
II
maximum speed), the ventilators work when a pre-set

TECHNICAL FEATURES

POWER SUPPLY
230 V~ ±10% 50 Hz
DIMENSIONS
120 x 74 x 51 mm
CONTAINER
Self-extinguishing ABS IP40 V0
INSERTO 70 L
6096700 – EN

Publicité

Table des Matières
loading

Table des Matières