6.1
Cleaning the Interior
• Cartridge bed (14, Fig� 1):
With the pressure plates (9, Fig� 1) retracted, the cartridge bed is easily accessible for cleaning�
• Pressure plates (9, Fig� 1) and spindle cover (10, Fig� 1):
If the cover is closed and with no installed cartridge, the pressure plates can be retracted to the appro-
priate position to allow residue to be removed from the pressure plates or the spindle covers�
NEVER clean the spindles (11, Fig. 1) themselves. The grease applied to spindles is necessary for
the unit's proper function.
Tip:
Remnants of impression material are most easily removed with a dry cloth or paper towel.
In addition to wiping with a moist cloth, the following cleaning agents are approved:
• Incidur Spray (Ecolab)
• Incides N wipes (Ecolab)
Ensure adequate ventilation after using these agents to prevent an explosion-prone area�
6.2
Pressure Disc Replacement
The pressure plates (9, Fig� 1) are subject to wear as a result of their rubbing against the inner cartridge
wall (20, Fig� 1)�
Highly worn pressure plates may cause damage the foil bag in the cartridge holder (20, Fig� 1)�
Moreover, an improperly installed cartridge may cause a crack in the pressure plates�
This is why the pressure plates are available as spare parts�
The tools required for replacing the parts as well as a description of the steps to take are provided with
the spare part�
6.3
Unit Cover Replacement
The equipment cover (8, Fig� 1) is available as a spare part�
The spare parts are supplied with the necessary tool and installation instructions�
6.4
Fuse Replacement
Before replacing the fuse, disconnect the unit from the mains power supply by unplugging the
power cord from the wall outlet.
Only replace fuses with new ones that have the same rating as those being replaced� Refer to the
„Technical Specifications" section.
Never use fuses with a higher rating
⇒ Unplug the unit�
⇒ Pull the fuse holder (17) out�
⇒ Remove the defective fuse and insert a new one�
⇒ Push the fuse holder back in, making sure it is completely seat-
ed�
6.5
Spare Parts
You can find components subject to wear and the spare parts on
the spare part list in the internet at www.renfert.com/p918�
Enter the following item number: 6000 0000�
The components excluded from the warranty (such as consum-
ables or parts subject to wear and tear) are marked on the spare
part list�
Serial number and date of manufacturing are shown on the type
plate of the unit�