NOTE: If the fan motor plug is
connected to the fan housing
receptacle, unplug so the
blower assembly can be
completely removed.
2.
Run wiring from an approved wall switch carrying the appropriate rating. One neutral
(White), one ground (green or bare copper), and three hot (Black, Purple, Yellow leads
connected to the switch, one for each function). Secure the electrical wires to the
housing with an approved electrical connector. Make sure you leave enough wiring in the
box to make the connection to the fan's receptacle.
3.
From where you have chosen to access the fan's junction box, connect the White wire from
the house to the two White wires from the fan. Connect one Hot (Black) wire from the wall
switch to the Black wire from the fan (this is the fan control). Connect second Hot (Purple)
wire from the wall switch to the Purple wire from the fan (this is the night light control).
Connect the third Hot (Yellow) wire from the wall switch to the Yellow wire from the fan (this
is the main light control). Connect the ground wire (green or bare copper) from the house to
the Green wire from the fan (Figure 8). Use approved methods for all connections.
Supply from
house
White
Ground
Figure 8
NOTE: The fan's receptacle wires might need to be pulled outside compartment for connection.
Only pull the three loose wires outside of compartment. Additional wires will be present.
4.
Carefully tuck wires back inside wire compartment and replace wire compartment cover
securing with the screw that was removed earlier.
SECTION 6
Completing the Installation
1.
Use a sealant appropriate for contact with the building materials present and for the
temperature requirements of the installation to prevent air leakage from unconditioned
spaces is recommended. If gaps between unit housing and ceiling are great, additional
material (backing rod, ceiling material) may be required.
NOTE: This fan is rated for direct insulation contact (Type IC) and it is recommended that this fan
be completely covered by insulation in order to reduce heat loss or gain to unconditioned space.
2.
If the fan's blower assembly was removed during the wiring process, reinstall the blower
by reversing the directions in Step 1b in Section 5 Wiring.
3.
Connect the fan wire harness by plugging the 3 pin quick connect end into the receptacle
located on the side of the wire compartment cover. Confirm that the 5 pin quick connect
end is plugged into the receptacle from the blower assembly. Connect the light wire harness
by plugging the 3 pin rectangular quick connect end into the receptacle located at the top of
the wire compartment. These cords will only fit one way into the receptacles (Figure 9).
210572203 Rev. K 5-14
All manuals and user guides at all-guides.com
Screw
Compartment
Figure 7
Hot
(Black)
Hot
(Purple)
Hot (Yellow)
Wire
Cover
Figure 9
4.
Install the included 26 watt fluorescent lamp into the lamp holder by lining up the pins on
the lamp base to the socket of the lamp holder and turning the lamp body clockwise until
the lamp snaps into place and is firmly seated in the lamp holder. Install a 4 watt maximum
type C7 (candelabra base) night light (not included) into the side lamp holder (Figure 10).
Lamp
Figure 10
5.
Install the reflector onto the grill by placing the slots on the side of the reflector over the
lens clips near the center of the grill. While squeezing the middle of the reflector, slide it so
that the plastic notches rest under the lens clips and the reflector feels secure (Figure 11).
Slot
Figure 11
6.
Install the grill (with reflector) by squeezing the two ends of the springs together and installing
them up into the slots on the fan's housing. Push the grill up into position (Figure 12).
Figure 12
7.
Restore power and test your installation.
www.airkinglimited.com
Night Light
Socket
Pin
Lamp Holder
Clip
3 of 12