Masquer les pouces Voir aussi pour AKF50:

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

IMPORTANT INSTRUCTIONS -
Models: AKF50, AKF80,
AKF100
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
electric shock and injury to person, including the following:
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND
INJURY TO PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer.If you have
questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent power
from being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND
INJURY TO PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to prevent
back drafting. Follow the heating equipment manufacturer's guideline
and safety standards such as those published by the National Fire
Protection Association (NFPA) and the American Society for Heating,
Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
210572203 Rev. K 5-14
All manuals and user guides at all-guides.com
OPERATING MANUAL
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
SAVE THESE INSTRUCTIONS
CAUTION:
EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS.
d) Ducted fans must always be vented to the outdoors.
e) This unit must be grounded.
f) To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. off power unit.
g) Read all instructions before installing or using exhaust fan.
WARNING:
USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE.
a) If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected to a
GFCI (Ground Fault Circuit Interrupter) – protected branch circuit.
b) Do not install in a ceiling with thermal insulation value greater
than R40.
WARNING:
www.airkinglimited.com
Exhaust Fan with Light
FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, DO NOT
DO NOT USE IN KITCHENS.
1 of 12

Publicité

Table des Matières
loading

Sommaire des Matières pour AirKing AKF50

  • Page 1 All manuals and user guides at all-guides.com IMPORTANT INSTRUCTIONS - OPERATING MANUAL Models: AKF50, AKF80, Exhaust Fan with Light AKF100 READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2: Installation Instructions

    All manuals and user guides at all-guides.com INSTALLATION INSTRUCTIONS SECTION 4 Ducting CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE CAUTION: ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL STARTING INSTALLATION. BUILDING CODES. SECTION 1 Connect the ducting to the fan’s duct collar (Figure 4). Secure in place using tape Preparing the Exhaust Fan or screw clamp.
  • Page 3 All manuals and user guides at all-guides.com NOTE: If the fan motor plug is Wire Screw connected to the fan housing Compartment receptacle, unplug so the Cover blower assembly can be completely removed. Figure 7 Figure 9 Run wiring from an approved wall switch carrying the appropriate rating. One neutral (White), one ground (green or bare copper), and three hot (Black, Purple, Yellow leads Install the included 26 watt fluorescent lamp into the lamp holder by lining up the pins on connected to the switch, one for each function).
  • Page 4: Troubleshooting Guide

    All manuals and user guides at all-guides.com SECTION 7 CAUTION: ALLOW BULBS TO COOL BEFORE REPLACING. Use and Care Changing the Lamp: Disconnect power to the unit. Remove grill by pulling downward on grill and squeezing grill springs together to release from housing (Figure 12). Remove CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE Reflector from grill by sliding the reflector notches from beneath the lens clips on grill.
  • Page 5: Replacement Parts Diagram

    Blower Assembly 5S2202029 Collar Assembly 5S1299111 Light Assembly 5S1202798 Light Harness 5S1299806 Glass Lens 5S5202001 Motor Cap Harness - AKF50 5S9202508 Grill 5S1202020 Motor Cap Harness - AKF80 5S9202502 Lens Clips 5S1202021 Motor Cap Harness - AKF100 5S9202505 Grill Springs...
  • Page 6 All manuals and user guides at all-guides.com NOTES 210572203 Rev. K 5-14 www.airkinglimited.com 6 of 12...
  • Page 7 All manuals and user guides at all-guides.com INSTRUCTIONS IMPORTANTES – MANUEL D’OPÉRATION Ventilateur combiner, comprend Modèles: AKF50, AKF80, lumière et ventilation AKF100 LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT.
  • Page 8 All manuals and user guides at all-guides.com INSTRUCTIONS D’INSTALLATION SECTION 4 Conduits ATTENTION : VOUS ASSURER QUE L’ALIMENTATION EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER L’INSTALLATION. ATTENTION : TOUS LES CONDUITS DOIVENT ÊTRE SECTION 1 CONFORMES AUX CODES DU BÂTIMENT LOCAUX ET NATIONAUX. Préparation du Ventilateur d’évacuation Raccorder le conduit au collet de conduit du ventilateur (Figure 4).
  • Page 9 All manuals and user guides at all-guides.com REMARQUE : si le raccord du moteur de Couvercle du ventilateur est raccordé au réceptacle Compartiment du châssis, le débrancher afin que l’assemblage de la soufflante soit de Câblage complètement enlevé. Figure 7 Figure 9 Courir le câblage à...
  • Page 10: Guide De Dépannage

    All manuals and user guides at all-guides.com SECTION 7 Remplacer la lampe : coupez l’alimentation de l’appareil. Retirez la grille en tirant vers le bas sur la grille et en serrant ensemble les ressorts de la grille pour libérer de logement Utilisation et entretien (Figure 12).
  • Page 11: Diagramme Des Pièces De Remplacement

    Assemblée de collier 5S1299111 Assemblement de lumière 5S1202798 Harnais de la Lumière 5S1299806 Lentilles de Verre 5S5202001 Harnais du Capuchon du Moteur - AKF50 5S9202508 Grille 5S1202020 Harnais du Capuchon du Moteur - AKF80 5S9202502 Clip de Lentilles 5S1202021 Harnais du Capuchon du Moteur - AKF100...
  • Page 12 All manuals and user guides at all-guides.com REMARQUE 210572203 Rev. K 5-14 www.airkinglimited.com 12 of 12...

Ce manuel est également adapté pour:

Akf80Akf100

Table des Matières