Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

IMPORTANT INSTRUCTIONS -
Models: AK150LS, AK150H,
E Series (Single Speed)
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN
THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL
When using electrical appliances, basic precautions should
always be followed to reduce the risk of fire, electric shock and
WARNING:
OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer.If you have
questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent power
from being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
WARNING:
OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to prevent
back drafting. Follow the heating equipment manufacturer's guideline
and safety standards such as those published by the National Fire
Protection Association (NFPA) and the American Society for Heating,
Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
6728035 Rev. R 12-18
OPERATING MANUAL
INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
injury to person, including the following:
TO REDUCE THE RISK
TO REDUCE THE RISK
SAVE THESE INSTRUCTIONS
CAUTION:
DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE
MATERIALS AND VAPORS.
d) Ducted fans must always be vented to the outdoors.
e) If this unit is to be installed over a tub or shower, it must be marked
as appropriate for the application and be connected to a GFCI (Ground
Fault Circuit Interrupter) – protected branch circuit.
f) This unit must be grounded.
g) To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. off power unit.
h) Read all instructions before installing or using exhaust fan.
i)
Suitable for use with electronic speed control device.
WARNING:
WARNING:
OUTSIDE OF THE BUILDING HAS A STRONG EFFECT
ON THE AIR FLOW, NOISE AND ENERGY USE OF THE FAN. USE
THE SHORTEST, STRAIGHTEST DUCT ROUTING POSSIBLE FOR
BEST PERFORMANCE, AND AVOID INSTALLING THE FAN WITH
SMALLER DUCTS THAN RECOMMENDED. INSULATION AROUND
THE DUCTS CAN REDUCE ENERGY LOSS AND INHIBIT MOLD
GROWTH. FANS INSTALLED WITH EXISTING DUCTS MAY NOT
ACHIEVE THEIR RATED AIRFLOW.
www.airkinglimited.com
Exhaust Fan
FOR GENERAL VENTILATING USE ONLY.
DO NOT USE IN KITCHENS.
THE DUCTING FROM THIS FAN TO THE
1 of 16

Publicité

Table des Matières
loading

Sommaire des Matières pour AirKing E Serie

  • Page 1 IMPORTANT INSTRUCTIONS - OPERATING MANUAL Models: AK150LS, AK150H, Exhaust Fan E Series (Single Speed) READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION.
  • Page 2 SECTION 4 INSTALLATION INSTRUCTIONS Ducting CAUTION: MAKE SURE POWER IS SWITCHED OFF AT NOTE: 6" OR LARGER RIGID DUCT IS RECOMMENDED FOR BEST PERFORMANCE. SERVICE PANEL BEFORE STARTING INSTALLATION. CAUTION: SECTION 1 ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES. Preparing the Exhaust Fan NOTE: The ducting from this fan to the outside of the building has a strong effect on the air Unpack fan from the carton and confirm that all pieces are present.
  • Page 3 Motion Sensing Models Run wiring carrying the appropriate rating. One neutral (white), one ground (green or Screw bare copper) and one hot (black). Secure the electrical wires to the housing with an approved electrical connector. Make sure you leave enough wiring in the box to make the connection to the fan’s receptacle.
  • Page 4: Completing The Installation

    the screw holes on the inside of the housing and press flange in place so it is tight against the ceiling. Reinstall ceiling flange mounting screws inside the housing (Figure 16). Black Black Switch (by others) Screws Neutral (White) Neutral (White) Green Ground (Green or Bare) Ceiling...
  • Page 5 SECTION 9 1b. To adjust the setting, while the sensor is still flashing from Step 1a, press the button the number of times that corresponds with the amount of time you desire, for instance 3 times Activating the Boost Speed (E models ONLY) sets the delay to 5 minutes (see numbers in Step 1).
  • Page 6: Troubleshooting Guide

    Troubleshooting Guide Trouble Probable Cause Suggested Remedy 1. Fan does not operate when the switch is on. A fuse may be blown or a circuit tripped. Replace fuse or reset circuit breaker. Connector plug from motor is not plugged in. 1b. Turn off power to unit.
  • Page 7: Replacement Parts Diagram

    REPLACEMENT PARTS DIAGRAM All Models Qty. Description Replacement Part # Mounting Rails 5S1299002 6" Metal Collar Assembly 5S5299100 Grill Springs 5S1202046 Ceiling Flange 5S1202050 Mounting Channel 5S1202123 Blower Assembly 5S2239008 Specific to Models E80S, E110S, E130S Qty. Description Replacement Part # Grill 5S1202048 Wire Compartment Assembly - E80S...
  • Page 8 NOTES: 6728035 Rev. R 12-18 www.airkinglimited.com 8 of 16...
  • Page 9: Ventilateur D'évacuation

    INSTRUCTIONS IMPORTANTES – MODE D’EMPLOI Modéles : AK150LS, AK150H, Ventilateur d’Évacuation Série E (seule vitesse) LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ.
  • Page 10 SECTION 4 INSTRUCTIONS D’INSTALLATION Conduits ATTENTION : VOUS ASSURER QUE L’ALIMENTATION NOTE: UN CONDUIT PLUS RIGIDE DE 6 PO OU PLUS EST RECOMMANDE POUR UNE EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER MEILLEURE PERFORMANCE. L’INSTALLATION. ATTENTION : SECTION 1 TOUS LES CONDUITS DOIVENT ÊTRE CONFORMES AUX CODES DU BÂTIMENT LOCAUX ET NATIONAUX.
  • Page 11: Couvercle Du Compartiment De Câblage

    Compartiment de Câblage Extérieur : Enlever la vis du couvercle du compartiment à Modèles avec détection de mouvement câblage et mettre ce couvercle dans un endroit fiable (Figure 5). Posez le câblage portant la spécification appropriée. Un neutre (blanc), un de terre (vert ou cuivre dénudé), et un chaud (noir).
  • Page 12: Complétion De L'installation

    Installez la bride de montage au plafond pour couvrir tous les espaces qui existent entre Commutateur le boîtier et le plafond fini. Placez un scellant (non fourni) sur le bord intérieur de la bride (par d’autres) de montage au plafond pour assurer que la bride est scellée au plafond. Alignez les trous Noir Noir de vis dans la bride de montage au plafond avec les trous de vis à...
  • Page 13: Réglage De L'humidostat

    SECTION 9 1b. Pour ajuster le réglage, tandis que le capteur continue de clignoter à partir de l’étape 1a, appuyez sur le bouton le nombre de fois qui correspond à la quantité de temps que vous Activation de la vitesse d’impulsion (modèles E seulement) désirez, par exemple 3 fois définit le délai de 5 minutes (voir les numéros à...
  • Page 14: Guide De Dépannage

    Guide de dépannage Trouble Cause Possible Solution Suggérée 1. Le ventilateur ne fonctionne pas lorsque 1a. Un fusible peut être grillé ou un disjoncteur Remplacer le fusible ou réinitialiser le disjoncteur. l’interrupteur est à la position en marche. peut être décle.nché. 1b.
  • Page 15: Diagramme Des Pièces De Remplacement

    DIAGRAMME DES PIÈCES DE REMPLACEMENT Tous les modèles # de pièce de Qté. Description remplacement Traverses de Montage 5S1299002 Particularités des modèles E80SG, E130SG Assemblée de collier en métal de 6 po 5S5299100 Ressorts de la grille 5S1202046 # de pièce de Qté.
  • Page 16 REMARQUE: 6728035 Rev. R 12-18 www.airkinglimited.com 16 of 16...

Ce manuel est également adapté pour:

Ak150lsAk150h

Table des Matières