Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

IMPORTANT INSTRUCTIONS -
ELGH Series
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN
THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL
When using electrical appliances, basic precautions should
always be followed to reduce the risk of fire, electric shock and
WARNING:
OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer.If you have
questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent power
from being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
WARNING:
OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to prevent
back drafting. Follow the heating equipment manufacturer's guideline
and safety standards such as those published by the National Fire
Protection Association (NFPA) and the American Society for Heating,
Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
6727914 Rev.D 4-17
OPERATING MANUAL
INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
injury to person, including the following:
TO REDUCE THE RISK
TO REDUCE THE RISK
SAVE THESE INSTRUCTIONS
d) Ducted fans must always be vented to the outdoors.
e) If this unit is to be installed over a tub or shower, it must be marked
as appropriate for the application and be connected to a GFCI (Ground
Fault Circuit Interrupter) – protected branch circuit.
f) Do not install in a ceiling with thermal insulation value greater than
R40.
g) This unit must be grounded.
h) To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. off power unit.
i)
Read all instructions before installing or using exhaust fan.
j)
Suitable for use with electronic speed control device.
WARNING:
WARNING:
OUTSIDE OF THE BUILDING HAS A STRONG EFFECT
ON THE AIR FLOW, NOISE AND ENERGY USE OF THE FAN. USE
THE SHORTEST, STRAIGHTEST DUCT ROUTING POSSIBLE FOR
BEST PERFORMANCE, AND AVOID INSTALLING THE FAN WITH
SMALLER DUCTS THAN RECOMMENDED. INSULATION AROUND
THE DUCTS CAN REDUCE ENERGY LOSS AND INHIBIT MOLD
GROWTH. FANS INSTALLED WITH EXISTING DUCTS MAY NOT
ACHIEVE THEIR RATED AIRFLOW.
www.airkinglimited.com
Exhaust Fan with Light
CAUTION:
FOR GENERAL VENTILATING USE ONLY.
DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE
MATERIALS AND VAPORS.
DO NOT USE IN KITCHENS.
THE DUCTING FROM THIS FAN TO THE
1 of 12

Publicité

Table des Matières
loading

Sommaire des Matières pour AirKing ELGH Serie

  • Page 1 IMPORTANT INSTRUCTIONS - OPERATING MANUAL ELGH Series Exhaust Fan with Light READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2 SECTION 4 INSTALLATION INSTRUCTIONS Ducting CAUTION: MAKE SURE POWER IS SWITCHED OFF AT NOTE: 6" OR LARGER RIGID DUCT IS RECOMMENDED FOR BEST PERFORMANCE. SERVICE PANEL BEFORE STARTING INSTALLATION. CAUTION: SECTION 1 ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES. Preparing the Exhaust Fan NOTE: The ducting from this fan to the outside of the building has a strong effect on the air Unpack fan from the carton and confirm that all pieces are present.
  • Page 3 NOTE: The fan’s receptacle wires might need to be pulled outside compartment for connection. Only pull the five loose wires outside of compartment. Additional wires will be present. Screw NOTE: Unit must be grounded according to all local and national codes. Dual Speed Models Continuous Ventilation: For two speed fans wired for continuous ventilation, connect Wire...
  • Page 4 Locate the motion sensor on the fan’s grill and press the button 10 times. The LED on the sensor will then flash the number of times to indicate the current setting, this will Screws repeat 3 times: 1 time = 0 minutes 4 times = 45 minutes 2 times = 15 minutes 5 times = 60 minutes...
  • Page 5: Troubleshooting Guide

    CALIFORNIA RESIDENTS ONLY: WARNING: THIS PRODUCT CAN EXPOSE YOU TO A CHEMICAL [OR CHEMICALS] KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER. WARNING: THIS PRODUCT CAN EXPOSE YOU TO A CHEMICAL [OR CHEMICALS] KNOWN TO THE STATE OF CALIFORNIA TO CAUSE REPRODUCTIVE TOXICITY.
  • Page 6: All Models

    REPLACEMENT PARTS DIAGRAM All Models Specific to Models EL80SGH, EL130SGH Qty. Description Replacement Part # Qty. Description Replacement Part # Mounting Rails 5S1299002 Wire Compartment Assembly - EL80SGH 5S1250139 6" Metal Collar Assembly 5S5299100 Wire Compartment Assembly - EL130SGH 5S1250135 Grill Springs 5S1202046 Specific to Models EL80DGH, EL130DGH...
  • Page 7: Ventilateur Combiner, Comprend Lumière Et Ventilation

    INSTRUCTIONS IMPORTANTES – MODE D’EMPLOI Ventilateur combiner, comprend Série ELGH lumière et ventilation LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À...
  • Page 8 SECTION 4 INSTRUCTIONS D’INSTALLATION Conduits ATTENTION : VOUS ASSURER QUE L’ALIMENTATION NOTE: UN CONDUIT PLUS RIGIDE DE 6 PO OU PLUS EST RECOMMANDE POUR UNE EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER MEILLEURE PERFORMANCE. L’INSTALLATION. ATTENTION : TOUS LES CONDUITS DOIVENT ÊTRE CONFORMES SECTION 1 AUX CODES DU BÂTIMENT LOCAUX ET NATIONAUX.
  • Page 9: Complétion De L'installation

    REMARQUE : Les fils du réceptacle du ventilateur pourraient nécessiter d’être tirés à l’extérieur du compartiment pour le raccordement. Tirer uniquement les trois fils lâches à l’extérieur du compartiment. Des fils additionnels y sont présents. REMARQUE : L’unité doit être mise à la terre selon les codes locaux et nationaux. Modèles avec une vitesse double Ventilation continue: Pour les ventilateurs à...
  • Page 10 REMARQUE : Il s’agit d’un minimum de temps que le ventilateur fonctionne. Si la salle est occupée plus longtemps, le ventilateur continuera de fonctionner jusqu’à ce que la salle est vide et le temps du délai d’occupation s’est écoulé. Localisez le détecteur de mouvement sur le gril du ventilateur et appuyez sur le bouton 10 fois.
  • Page 11: Guide De Dépannage

    Remplacement de l’ampoule : débrancher l’alimentation de l’unité. Ouvrez l’objectif de RÉSIDENTS DE LA CALIFORNIE UNIQUEMENT : lumière sur la grille en poussant dans l’objectif pour lui permettre de s’ouvrir. AVERTISSEMENT : CE PRODUIT PEUT VOUS EXPOSER Ampoule LED : Retirez la lampe en tournant doucement la base de la lampe dans À...
  • Page 12: Diagramme Des Pièces De Remplacement

    DIAGRAMME DES PIÈCES DE REMPLACEMENT Tous les modèles Particularités des modèles EL80SGH, EL130SGH # de pièce de # de pièce de Qté. Description remplacement Qté. Description remplacement Traverses de Montage 5S1299002 Assemblée du compartiment du fil - EL80SGH 5S1250139 Assemblée de collier en métal de 6 po 5S5299100 Assemblée du compartiment du fil - EL130SGH 5S1250135...

Table des Matières