Télécharger Imprimer la page

AirKing EL Serie Instructions Importantes – Mode D'emploi

Masquer les pouces Voir aussi pour EL Serie:

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

IMPORTANT INSTRUCTIONS -
EL Series (Single Speed)
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN
THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL
When using electrical appliances, basic precautions should
always be followed to reduce the risk of fire, electric shock and
WARNING:
OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer.If you have
questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent power
from being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
WARNING:
OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to prevent
back drafting. Follow the heating equipment manufacturer's guideline
and safety standards such as those published by the National Fire
Protection Association (NFPA) and the American Society for Heating,
Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
6727915 Rev. G 12-18
OPERATING MANUAL
INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
injury to person, including the following:
TO REDUCE THE RISK
TO REDUCE THE RISK
SAVE THESE INSTRUCTIONS
d) Ducted fans must always be vented to the outdoors.
e) If this unit is to be installed over a tub or shower, it must be marked
as appropriate for the application and be connected to a GFCI (Ground
Fault Circuit Interrupter) – protected branch circuit.
f) Do not install in a ceiling with thermal insulation value greater than
R40.
g) This unit must be grounded.
h) To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. off power unit.
i)
Read all instructions before installing or using exhaust fan.
j)
Suitable for use with electronic speed control device.
WARNING:
WARNING:
OUTSIDE OF THE BUILDING HAS A STRONG EFFECT
ON THE AIR FLOW, NOISE AND ENERGY USE OF THE FAN. USE
THE SHORTEST, STRAIGHTEST DUCT ROUTING POSSIBLE FOR
BEST PERFORMANCE, AND AVOID INSTALLING THE FAN WITH
SMALLER DUCTS THAN RECOMMENDED. INSULATION AROUND
THE DUCTS CAN REDUCE ENERGY LOSS AND INHIBIT MOLD
GROWTH. FANS INSTALLED WITH EXISTING DUCTS MAY NOT
ACHIEVE THEIR RATED AIRFLOW.
www.airkinglimited.com
Exhaust Fan with Light
CAUTION:
FOR GENERAL VENTILATING USE ONLY.
DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE
MATERIALS AND VAPORS.
DO NOT USE IN KITCHENS.
THE DUCTING FROM THIS FAN TO THE
1 of 16

Publicité

loading

Sommaire des Matières pour AirKing EL Serie

  • Page 1 IMPORTANT INSTRUCTIONS - OPERATING MANUAL EL Series (Single Speed) Exhaust Fan with Light READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2 SECTION 4 INSTALLATION INSTRUCTIONS Ducting CAUTION: MAKE SURE POWER IS SWITCHED OFF AT NOTE: 6" OR LARGER RIGID DUCT IS RECOMMENDED FOR BEST PERFORMANCE. SERVICE PANEL BEFORE STARTING INSTALLATION. CAUTION: SECTION 1 ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES. Preparing the Exhaust Fan NOTE: The ducting from this fan to the outside of the building has a strong effect on the air Unpack fan from the carton and confirm that all pieces are present.
  • Page 3 Humidity Sensing Models Screw Wiring the Fan: For proper operation the humidity sensing fan will require a 3 way switch (not included). Run wiring between the fan and the switch location. Make sure you leave enough wiring in each box to make the connections. At the switch box connect the black wire from the house to the common terminal of the switch.
  • Page 4 SECTION 6 STANDARD AND HUMIDITY SENSING MODELS: Install the grill by squeezing the springs together and installing it up into the slot furthest from the wire compartment on Completing the Installation the fans housing. Attach the 4 pin quick connect from the grill to the 4 pin connector on the top of the wire cover.
  • Page 5 SECTION 9 To adjust the setting, while the sensor is still flashing from Step 1a, press the button the number of times that corresponds with the amount of time you desire, for instance 3 times Activating the Boost Speed sets the delay to 5 minutes (see numbers in Step 1). The sensor will then flash the number of times for the new setting 3 times before exiting back to the programming mode.
  • Page 6 Troubleshooting Guide Trouble Probable Cause Suggested Remedy 1. Fan does not operate when the switch is on. A fuse may be blown or a circuit tripped. Replace fuse or reset circuit breaker. Connector plug from motor is not plugged in. 1b. Turn off power to unit.
  • Page 7 REPLACEMENT PARTS DIAGRAM All Models Qty. Description Replacement Part # Mounting Rails 5S1299002 6" Metal Collar Assembly 5S5299100 Grill Springs 5S1202046 Ceiling Flange 5S1202050 Specific to Models EL80SGH, EL130SGH Mounting Channel 5S1202123 Blower Assembly 5S2239008 Qty. Description Replacement Part # 8 Watt Lamp 5S1250001 Grill Assembly...
  • Page 8 NOTES: www.airkinglimited.com 6727915 Rev. G 12-18 8 of 16...
  • Page 9 INSTRUCTIONS IMPORTANTES – MODE D’EMPLOI Ventilateur combiner, comprend Série EL (seule vitesse ) lumière et ventilation LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ.
  • Page 10 SECTION 4 INSTRUCTIONS D’INSTALLATION Conduits ATTENTION : VOUS ASSURER QUE L’ALIMENTATION NOTE: UN CONDUIT PLUS RIGIDE DE 6 PO OU PLUS EST RECOMMANDE POUR UNE EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER MEILLEURE PERFORMANCE. L’INSTALLATION. ATTENTION : TOUS LES CONDUITS DOIVENT ÊTRE CONFORMES SECTION 1 AUX CODES DU BÂTIMENT LOCAUX ET NATIONAUX.
  • Page 11 Modèles avec détection d’humidité Câblage du ventilateur : Pour un bon fonctionnement, le ventilateur de détection d’humidité exigera un interrupteur à 3 voies (non inclus). Faites passer le câblage entre le ventilateur et l’emplacement du commutateur. Assurez-vous de laisser suffisamment de câblage dans chaque boîte pour faire les connexions.
  • Page 12 SECTION 6 REMARQUE : Si le boîtier est monté très loin ou pas assez loin dans le plafond pour pouvoir fixer solidement la bride, desserrez le canal de montage et ajustez le boîtier vers le haut ou Complétion de l’installation vers le bas sur les rails.
  • Page 13 SECTION 9 Pour ajuster le réglage, tandis que le capteur continue de clignoter à partir de l’étape 1a, appuyez sur le bouton le nombre de fois qui correspond à la quantité de temps que Activation de la vitesse d’impulsion vous désirez, par exemple 3 fois définit le délai de 5 minutes (voir les numéros à l’étape 1).
  • Page 14 Guide de dépannage Trouble Cause Possible Solution Suggérée 1. Le ventilateur ne fonctionne pas lorsque 1a. Un fusible peut être grillé ou un disjoncteur Remplacer le fusible ou réinitialiser le disjoncteur. l’interrupteur est à la position en marche. peut être décle.nché. 1b.
  • Page 15 DIAGRAMME DES PIÈCES DE REMPLACEMENT Tous les modèles # de pièce de Qté. Description remplacement Traverses de Montage 5S1299002 Assemblée de collier en métal de 6 po 5S5299100 Ressorts de la grille 5S1202046 Bride du plafond 5S1202050 Particularités des modèles EL80SGH, EL130SGH Canal de montage 5S1202123 Assemblée de la Soufflante...
  • Page 16 REMARQUE: www.airkinglimited.com 6727915 Rev. G 12-18 16 of 16...

Ce manuel est également adapté pour:

El80sghEl130sghEl80shEl130shEl80sEl130s ... Afficher tout