Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

IMPORTANT INSTRUCTIONS -
EL Series (Dual Speed)
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN
THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL
When using electrical appliances, basic precautions should
always be followed to reduce the risk of fire, electric shock and
WARNING:
OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer.If you have
questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent power
from being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
WARNING:
OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to prevent
back drafting. Follow the heating equipment manufacturer's guideline
and safety standards such as those published by the National Fire
Protection Association (NFPA) and the American Society for Heating,
Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
6727913 Rev. H 12-18
OPERATING MANUAL
INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
injury to person, including the following:
TO REDUCE THE RISK
TO REDUCE THE RISK
SAVE THESE INSTRUCTIONS
d) Ducted fans must always be vented to the outdoors.
e) If this unit is to be installed over a tub or shower, it must be marked
as appropriate for the application and be connected to a GFCI (Ground
Fault Circuit Interrupter) – protected branch circuit.
f) Do not install in a ceiling with thermal insulation value greater than
R40.
g) This unit must be grounded.
h) To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. off power unit.
i)
Read all instructions before installing or using exhaust fan.
j)
Suitable for use with electronic speed control device.
WARNING:
WARNING:
OUTSIDE OF THE BUILDING HAS A STRONG EFFECT
ON THE AIR FLOW, NOISE AND ENERGY USE OF THE FAN. USE
THE SHORTEST, STRAIGHTEST DUCT ROUTING POSSIBLE FOR
BEST PERFORMANCE, AND AVOID INSTALLING THE FAN WITH
SMALLER DUCTS THAN RECOMMENDED. INSULATION AROUND
THE DUCTS CAN REDUCE ENERGY LOSS AND INHIBIT MOLD
GROWTH. FANS INSTALLED WITH EXISTING DUCTS MAY NOT
ACHIEVE THEIR RATED AIRFLOW.
www.airkinglimited.com
Exhaust Fan with Light
CAUTION:
FOR GENERAL VENTILATING USE ONLY.
DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE
MATERIALS AND VAPORS.
DO NOT USE IN KITCHENS.
THE DUCTING FROM THIS FAN TO THE
1 of 16

Publicité

Table des Matières
loading

Sommaire des Matières pour AirKing EL Serie

  • Page 1 IMPORTANT INSTRUCTIONS - OPERATING MANUAL EL Series (Dual Speed) Exhaust Fan with Light READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2 SECTION 4 INSTALLATION INSTRUCTIONS Ducting CAUTION: MAKE SURE POWER IS SWITCHED OFF AT NOTE: 6" OR LARGER RIGID DUCT IS RECOMMENDED FOR BEST PERFORMANCE. SERVICE PANEL BEFORE STARTING INSTALLATION. CAUTION: SECTION 1 ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES. Preparing the Exhaust Fan NOTE: The ducting from this fan to the outside of the building has a strong effect on the air flow, noise and energy use of the fan.
  • Page 3 NOTE: The yellow wire may contain a wire crimp nut which will have to be cut off and the wire stripped. Screw Motion Sensing Models For two speed fans wired for continuous ventilation, connect the White wires of the fan to the White (Neutral) wire from the power source.
  • Page 4: Completing The Installation

    Install the ceiling mounting flange to cover any gaps which exist between the housing Wire Compartment and the finished ceiling. Remove the two screws that connect the ceiling mounting flange to the housing. Put sealant (not provided) on inside edge of the ceiling mounting flange Black to ensure that the flange is sealed to the ceiling.
  • Page 5 SECTION 9 Open the light lens on the grill by pushing into the lens and allowing in to spring open. Install the 8 watt lamp (included) into the lamp holder by lining up the pins on the lamp Activating the Boost Speed base to the socket of the lamp holder and turning the lamp body clockwise until the lamp snaps into place and is firmly seated in the lamp holder.
  • Page 6: Troubleshooting Guide

    Troubleshooting Guide Trouble Probable Cause Suggested Remedy 1. Fan does not operate when the switch is on. A fuse may be blown or a circuit tripped. Replace fuse or reset circuit breaker. Connector plug from motor is not plugged in. 1b. Turn off power to unit.
  • Page 7: All Models

    REPLACEMENT PARTS DIAGRAM All Models Qty. Description Replacement Part # Mounting Rails 5S1299002 6" Metal Collar Assembly 5S5299100 Grill Springs 5S1202046 Ceiling Flange 5S1202050 Specific to Models EL80DH, EL130DH Mounting Channel 5S1202123 Blower Assembly 5S1239125 Qty. Description Replacement Part # 8 Watt Lamp 5S1250001 Grill Assembly...
  • Page 8 NOTES: www.airkinglimited.com 6727913 Rev. H 12-18 8 of 16...
  • Page 9: Ventilateur Combiner, Comprend Lumière Et Ventilation

    INSTRUCTIONS IMPORTANTES – MODE D’EMPLOI Ventilateur combiner, comprend Série EL (Double vitesse ) lumière et ventilation LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ.
  • Page 10 SECTION 4 INSTRUCTIONS D’INSTALLATION Conduits ATTENTION : VOUS ASSURER QUE L’ALIMENTATION NOTE: UN CONDUIT PLUS RIGIDE DE 6 PO OU PLUS EST RECOMMANDE POUR UNE EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER MEILLEURE PERFORMANCE. L’INSTALLATION. ATTENTION : TOUS LES CONDUITS DOIVENT ÊTRE CONFORMES SECTION 1 AUX CODES DU BÂTIMENT LOCAUX ET NATIONAUX.
  • Page 11: Couvercle Du Compartiment De Câblage

    REMARQUE : Le fil jaune peut contenir un écrou de fil à sertir qui devra être coupé et le fil dénudé. Modèles avec détection de mouvement Pour les ventilateurs à deux vitesses, raccordés pour une ventilation continue, connectez les fils blanc du ventilateur au fil blanc (neutre) de la source d’alimentation. Connectez le fil de terre de la maison au fil vert du boîtier du ventilateur.
  • Page 12: Complétion De L'installation

    Installez la bride de montage au plafond pour couvrir tous les espaces qui existent Compartiment du fil entre le boîtier et le plafond fini. Retirer les deux vis qui relient la bride de montage au boîtier. Placez un scellant (non fourni) sur le bord intérieur de la bride de montage au plafond Noir pour assurer que la bride est scellée au plafond.
  • Page 13: Programmation Du Capteur D'occupation

    SECTION 9 Ouvrez l’objectif de lumière sur la grille en poussant dans l’objectif pour lui permettre de s’ouvrir. Installez la lampe de 8 watts (incluse) dans la douille en alignant les broches de Activation de la vitesse d’impulsion la base de la lampe à la prise de la douille de lampe. Tournez le corps de la lampe dans le sens horaire jusqu’à...
  • Page 14: Guide De Dépannage

    Guide de dépannage Trouble Cause Possible Solution Suggérée 1. Le ventilateur ne fonctionne pas lorsque 1a. Un fusible peut être grillé ou un disjoncteur Remplacer le fusible ou réinitialiser le disjoncteur. l’interrupteur est à la position en marche. peut être décle.nché. 1b.
  • Page 15: Diagramme Des Pièces De Remplacement

    DIAGRAMME DES PIÈCES DE REMPLACEMENT Tous les modèles # de pièce de Qté. Description remplacement Traverses de Montage 5S1299002 Assemblée de collier en métal de 6 po 5S5299100 Ressorts de la grille 5S1202046 Bride du plafond 5S1202050 Particularités des modèles EL80DH, EL130DH Canal de montage 5S1202123 Assemblée de la Soufflante...
  • Page 16 REMARQUE: www.airkinglimited.com 6727913 Rev. H 12-18 16 of 16...

Ce manuel est également adapté pour:

El80d

Table des Matières