Screw
Figure 5
1b.
Internal Wire Compartment: If the motor is already installed in the housing, remove
the two screws holding the blower assembly in place. Lift up on the assembly and slide
it out of the tabs on the housing (Figure 6). Remove the wire compartment cover screw
and place the cover in a secure place (Figure 7).
Screws
Figure 6
NOTE: If the fan motor plug is connected to the fan housing receptacle, unplug so the blower
assembly can be completely removed.
Screw
Figure 7
Standard and Motion Sensing Models
2.
Secure the electrical wires to the housing with an approved electrical connector.
Connect the White wires of the fan to the White (Neutral) wire from the power source.
Connect the ground wire from the house to the green wire from the fan housing. Using
a properly grounded three function switch (not included) connect the Black wire from
the supply to the switch. Connect the Black wire (fan) from the fan housing to one of the
terminals on the switch. Connect the Red wire (light) from the fan housing to a separate
terminal on the switch. Connect the Purple wire (night light) from the fan housing to a
separate terminal on the switch (Figure 8). Use approved methods for all connections.
Neutral (White)
Neutral (White)
Green
Ground (Green or Bare)
Neutral (White)
Figure 8
NOTE: The fan's receptacle wires might need to be pulled outside compartment for connection.
Only pull the five loose wires outside of compartment. Additional wires will be present.
NOTE: Unit must be grounded according to all local and national codes.
6727915 Rev. G 12-18
Wire
Compartment
Cover
Plug
Tabs
Wire Compartment
Cover
NOTE: Wire compartment configuration
will be dependent on model.
Wire Compartment
Black
Red
Purple
Black
By others
Supply from house
Humidity Sensing Models
Wiring the Fan: For proper operation the humidity sensing fan will require a 3 way
3a.
switch (not included). Run wiring between the fan and the switch location. Make sure
you leave enough wiring in each box to make the connections. At the switch box
connect the black wire from the house to the common terminal of the switch. Connect
the black wire from the fan to one of the switched terminals on the switch. This position
will energize the automatic mode and the fan will energize upon a rise in humidity.
Connect the yellow wire from the fan to the other switched terminal on the switch. This
position will activate the Manual On feature and energize the fan. Properly connect the
ground and neutral (if applicable) mount the switch and the cover.
NOTE: The yellow wire may contain a wire crimp nut which will have to be cut off and
the wire stripped.
3b.
From where you have chosen to access the fan's junction box, connect the white wire
from the house to the white wires from the fan. Connect the wire from the automatic
position on the wall switch to the black wire from the fan, connect the wire from the
manual On position on the switch to the yellow wire from the fan. Connect the ground
wire from the house to the green wire from the fan housing (Figure 9). Use approved
methods for all connections.
NOTE: The yellow wire may contain a wire crimp nut which will have to be cut off and
the wire stripped.
3c.
Wiring the Lights: Using a properly grounded standard wall switch, connect the black
wire from the supply to one side of the switch. Connect the Red wire (light) from the fan
housing to one of the terminals on the switch. Connect the Purple wire (night light) from
the fan housing to a separate terminal on the switch (Figure 9). Use approved methods
for all connections.
Black
Figure 9
Motion and Humidity Sensing Models
4.
Secure the electrical wires to the housing with an approved electrical connector.
Connect the White wires of the fan to the White (Neutral) wire from the power source.
Connect the ground wire from the house to the green wire from the fan housing. Using
a properly grounded three function switch (not included) connect the Black wire from
the supply to the switch. Connect the Black wire (fan) from the fan housing to one of the
terminals on the switch. Connect the Red wire (light) from the fan housing to a separate
terminal on the switch. Connect the Purple wire (night light) from the fan housing to a
separate terminal on the switch (Figure 10). Use approved methods for all connections.
Neutral (White)
Neutral (White)
Neutral (White)
Figure 10
NOTE: The fan's receptacle wires might need to be pulled outside compartment for connection.
Only pull the five loose wires outside of compartment. Additional wires will be present.
NOTE: Unit must be grounded according to all local and national codes.
5.
Carefully tuck wire back inside wire compartment and replace wire compartment cover
securing with the screw that was removed earlier.
www.airkinglimited.com
Wire Compartment
Black
Yellow
Neutral (White)
Neutral (White)
Green
Ground (Green or Bare)
Black
Neutral (White)
Supply from house
Wire Compartment
Green
Ground (Green or Bare)
Black
Supply from house
Red
Purple
By others
Black
Red
Purple
By others
3 of 16