Table des Matières
Les langues disponibles

Les langues disponibles

Liens rapides

IMPORTANT INSTRUCTIONS -
Models: AK50LS, AK80LS-1, AK80,
AK90, AK110PN, AK110, AK130
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
electric shock and injury to person, including the following:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer.If
you have questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent back drafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA)
and the American Society for Heating, Refrigeration, and Air
Conditioning Engineers (ASHRAE), and the local code authorities.
c) When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
210952009 Rev. D 3-12
OPERATING MANUAL
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
SAVE THESE INSTRUCTIONS
d) Ducted fans must always be vented to the outdoors.
e) If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected to a
GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.
f) This unit must be grounded.
g) To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power unit.
h) NEVER place a switch where it can be reached from a tub or
shower.
i) Suitable for use with electronic speed control device.
j) Do not install into ceilings thermally insulated to a value greater
than R40.
CAUTION:
USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND
VAPORS.
WARNING:
k) Read all instructions before installing or using exhaust fan.
www.airkinglimited.com
Exhaust Fan
FOR GENERAL VENTILATING USE ONLY. DO NOT
DO NOT USE IN KITCHENS.
1 of 8
Table des Matières
loading

Sommaire des Matières pour AirKing AK80LS-1

  • Page 5: Ventilateur D'évacuation

    INSTRUCTIONS IMPORTANTES – MODE D’EMPLOI Modéles : AK50LS, AK80LS-1, AK80, Ventilateur d’Évacuation AK90, AK110PN, AK110, AK130 LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À...
  • Page 6: Nouvelle Construction

    INSTRUCTIONS D’INSTALLATION AVERTISSEMENT : VOUS ASSURER QUE L’ALIMENTATION EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER L’INSTALLATION. SECTION 1 Préparation du Ventilateur d’évacuation Solive Sortir le ventilateur de sa boite et confirmer que toutes les pièces sont présentes. En plus du ventilateur d’évacuation vous devriez avoir: Figure 3 1 - Grille 4 - Traverses de Montage...
  • Page 7: Utilisation Et Entretien

    1b. Compartiment de Câblage Intérieur: Enlever le vis retenant en place Regrouper soigneusement les fils à l’intérieur du compartiment pour le raccordement et replacer le couvercle du compartiment en le fixant l’ensemble venturi du ventilateur et soulever pour sortir l’assemblage hors du châssis (Figure 6).
  • Page 8: Garantie Limitée

    5S1999002 Fil de mise à la terre de calibre # 14 5S1999003 Vis #6 par 3/8 po 5S1999010 Couvercle de Câble Externe 5S1202007 Harnais du Capuchon du Moteur AK50LS 5S9202501 AK80LS-1 5S9202502 AK80 5S9202503 AK90 5S9202504 AK110PN 5S9202505 AK110 5S9202506...

Ce manuel est également adapté pour:

Ak50lsAk80Ak90Ak110pnAk110Ak130

Table des Matières