Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

IMPORTANT INSTRUCTIONS -
Models: AK965, AKF965
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
electric shock and injury to person, including the following:
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND
INJURY TO PERSON, OBSERVE THE FOLLOWING:
a) Use this heater only as described in this manual. Any other use not recommended
by the manufacturer may cause fire, electric shock, or injury to persons.
b) Operate heater only when grille is installed.
c) Before servicing or cleaning the unit, switch power off at service panel and
lock the service disconnecting means to prevent power from being switched on
accidentally. When the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the service panel.
d) Do not operate any heater after it malfunctions. Disconnect power at service
panel and have heater inspected by a reputable electrician before reusing.
e) Do not use outdoors.
f)
Do not insert or allow foreign objects to enter any ventilation or exhaust
opening as this may cause and electric shock or fire, or damage the heater.
g) To prevent a possible fire, do not block air intakes or exhaust in any manner.
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND
INJURY TO PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified person(s) in
accordance with all applicable codes and standards, including fire-related
construction.
b) For supply connections, use wires suitable for at least 75° C (167° F).
c) Use copper wire only.
d) Sufficient air is needed for proper combustion and exhausting of gases through
the flue (chimney) of fuel burning equipment to prevent back drafting. Follow
the heating equipment manufacturer's guideline and safety standards such
as those published by the National Fire Protection Association (NFPA) and the
American Society for Heating, Refrigeration, and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
e) When cutting or drilling into wall or ceiling, do not damage electrical wiring and
other hidden utilities.
965 Rev. D 5-14
All manuals and user guides at all-guides.com
OPERATING MANUAL
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
SAVE THESE INSTRUCTIONS
CAUTION:
EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS.
f)
A heater has hot and arcing or sparking parts inside. Do not use in areas where
gasoline, paint, or flammable vapors or liquids are used or stored.
g) Ducted fans must always be vented to the outdoors.
h) This unit must be grounded.
i)
To avoid motor bearing damage and noisy and/or unbalanced impellers, keep
drywall spray, construction dust, etc. off power unit.
j)
This heater is hot when in use. To avoid burns, do not let bare skin touch hot
surfaces.
k) Extreme caution is necessary when any heater is used by or near children or
invalids and whenever the heater is left operating and unattended.
IMPORTANT INSTRUCTIONS: Read all instructions before installing or using
exhaust fan.
WARNING:
USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE.
WARNING:
STALL ENCLOSURE.
WARNING:
WARNING:
SUPPLEMENTAL HEATER FOR USE WITH A TIMER OR A SWITCH. IT IS NOT
INTENDED TO BE USED AS THE PRIMARY SOURCE OF HEAT AND CONTROLLED
BY A THERMOSTAT.
Motor is thermally protected.
Electrical Ratings: AK965 - 120V, 60Hz., 15.65A
www.airkinglimited.com
Exhaust Fan with Heater
FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, DO NOT
DO NOT INSTALL OVER A TUB OR MOUNT IN A SHOWER
DO NOT USE IN KITCHENS.
THIS UNIT IS DESIGNED AND TESTED TO BE A
AKF965 - 120V, 60Hz., 15.20A
1 of 12

Publicité

loading

Sommaire des Matières pour AirKing AK965

  • Page 1 American Society for Heating, Refrigeration, and Air Conditioning Engineers Motor is thermally protected. (ASHRAE), and the local code authorities. Electrical Ratings: AK965 - 120V, 60Hz., 15.65A e) When cutting or drilling into wall or ceiling, do not damage electrical wiring and AKF965 - 120V, 60Hz., 15.20A other hidden utilities.
  • Page 2 All manuals and user guides at all-guides.com INSTALLATION INSTRUCTIONS CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION. Housing WARNING: TO REDUCE THE RISK OF FIRE, DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THE HEATER. SECTION 1 Joist Preparing the Exhaust Fan...
  • Page 3 All manuals and user guides at all-guides.com SECTION 4 Ducting CAUTION: Hot (Yellow) ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES. White Hot (Blue) Remove any tape that might be holding the damper in place. Connect the ducting to the fan’s duct collar (Figure 8) and secure in place using tape or screw clamp.
  • Page 4 All manuals and user guides at all-guides.com Remove grill from carton and open light lens area by pushing in on the two tabs of the Install the appropriate bulbs (not included) specific to your model: light lens and pulling outward from lens. The lens will swing open on the connector bars. AK965L: Install a 100 watt maximum, type A19 medium base incandescent bulb (not DO NOT remove the lens from the grill (Figure 12).
  • Page 5 All manuals and user guides at all-guides.com Troubleshooting Guide Trouble Probable Cause Suggested Remedy 1. Fan does not operate when the switch is on. A fuse may be blown or a circuit tripped. Replace fuse or reset circuit breaker. Connector plug from motor is not plugged in. 1b. Turn off power to unit. Remove Grill and plug motor into receptacle in housing.
  • Page 6 All manuals and user guides at all-guides.com NOTES 965 Rev. D 5-14 www.airkinglimited.com 6 of 12...
  • Page 7 All manuals and user guides at all-guides.com INSTRUCTIONS IMPORTANTES – MANUEL D’OPÉRATION Ventilateur d’évacuation Modèles: AK965, AKF965 avec chauffage LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À...
  • Page 8 All manuals and user guides at all-guides.com INSTRUCTIONS D’INSTALLATION ATTENTION : VOUS ASSURER QUE L’ALIMENTATION EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER L’INSTALLATION. Châssis AVERTISSEMENT: POUR RÉDUIRE LES RISQUES D’INCENDIE, NE PAS STOCKER NI UTILISER D’ESSENCE OU D’AUTRES VAPEURS ET LIQUIDES INFLAMMABLES À PROXIMITÉ...
  • Page 9 All manuals and user guides at all-guides.com SECTION 4 Conduits Fil Chaud ATTENTION : (Jaune) TOUS LES CONDUITS DOIVENT ÊTRE CONFORMES AUX CODES DU BÂTIMENT LOCAUX ET NATIONAUX. Blanc Enlever tout ruban adhésif qui pourrait retenir le clapet en place durant le transport et raccorder les conduits au collet du conduit du ventilateur (Figure 8).
  • Page 10 All manuals and user guides at all-guides.com SECTION 7 Enlever la grille de la boîte et ouvrir la section lentilles de lampe en poussant sur les deux onglets des lentilles de lampe et en tirant vers l’extérieur des lentilles. Les lentilles Mode d’emploi basculeront en position ouverte sur les barres connecteurs.
  • Page 11 All manuals and user guides at all-guides.com Guide de dépannage Trouble Cause Possible Solution Suggérée 1. Le ventilateur ne fonctionne pas lorsque 1a. Un fusible peut être grillé ou un disjoncteur Remplacer le fusible ou réinitialiser le disjoncteur. l’interrupteur est à la position en marche. peut être décle.nché.
  • Page 12 All manuals and user guides at all-guides.com NOTES 965 Rev. D 5-14 www.airkinglimited.com 12 of 12...

Ce manuel est également adapté pour:

Akf965