AirKing AK150LS Serie Manuel D'utilisation

Montrer les pouces Voir aussi pour AK150LS Serie:
Les langues disponibles

Les langues disponibles

Liens rapides

IMPORTANT INSTRUCTIONS -
Models: AK150LS, ESB Series
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
electric shock and injury to person, including the following:
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK
AND INJURY TO PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK
AND INJURY TO PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent back drafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA)
and the American Society for Heating, Refrigeration, and Air
Conditioning Engineers (ASHRAE), and the local code authorities.
c) When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6728035 Rev. F 5-14
Downloaded from
www.Manualslib.com
OPERATING MANUAL
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
SAVE THESE INSTRUCTIONS
manuals search engine
d) Ducted fans must always be vented to the outdoors.
e) If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected to a
GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.
f) This unit must be grounded.
g) To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power unit.
h) Suitable for use with electronic speed control device.
CAUTION:
FOR GENERAL VENTILATING USE ONLY. DO NOT
USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND
VAPORS.
WARNING:
i) Read all instructions before installing or using exhaust fan.
www.airkinglimited.com
Exhaust Fan
DO NOT USE IN KITCHENS.
1 of 12
Table des Matières
loading

Sommaire des Matières pour AirKing AK150LS Serie

  • Page 1 IMPORTANT INSTRUCTIONS - OPERATING MANUAL Models: AK150LS, ESB Series Exhaust Fan READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2: Installation Instructions

    SECTION 4 INSTALLATION INSTRUCTIONS Ducting CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE CAUTION: STARTING INSTALLATION. ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES. SECTION 1 Connect the ducting to the fan’s duct collar (Figure 4). Secure in place using tape Preparing the Exhaust Fan or screw clamp.
  • Page 3 SECTION 6 Completing the Installation Use a sealant appropriate for contact with the building materials present and for the temperature requirements of the installation to prevent air leakage from unconditioned Wire Compartment spaces is recommended. If gaps between unit housing and ceiling are great, additional Screw Cover material (backing rod, ceiling material) may be required.
  • Page 4 Once all setting have been made and the sensor will return to detection mode and the LED will flash when occupancy of the room is detected. SECTION 8 Setting the Humidistat This fan is equipped with a humidity sensor that automatically turns the fan on when humidity is above set point and off when humidity is at or below set point.
  • Page 5: Troubleshooting Guide

    Troubleshooting Guide Trouble Probable Cause Suggested Remedy 1. Fan does not operate when the switch is on. A fuse may be blown or a circuit tripped. Replace fuse or reset circuit breaker. Connector plug from motor is not plugged in. 1b. Turn off power to unit.
  • Page 6: Replacement Parts Diagram

    REPLACEMENT PARTS DIAGRAM All Models Qty. Description Replacement Part # Mounting Rails 5S1299002 6” Metal Collar Assembly 5S5299100 Grill Springs 5S1202046 Ceiling Flange 5S1202050 Mounting Channel 5S1239024 Specific to Models ESB80SG, ESB130SG Blower Assembly 5S2239008 Qty. Description Replacement Part # Wire Compartment Assembly - ESB80SG 5S1239832 Specific to Models ESB80S, ESB130S...
  • Page 7: Ventilateur D'évacuation

    INSTRUCTIONS IMPORTANTES – MODE D’EMPLOI Modéles : AK150LS, Série ESB Ventilateur d’Évacuation LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À...
  • Page 8 SECTION 4 INSTRUCTIONS D’INSTALLATION Conduits ATTENTION : VOUS ASSURER QUE L’ALIMENTATION EST COUPÉE AU ATTENTION : PANNEAU DE SERVICE AVANT DE COMMENCER L’INSTALLATION. TOUS LES CONDUITS DOIVENT ÊTRE CONFORMES AUX CODES DU BÂTIMENT LOCAUX ET NATIONAUX. SECTION 1 Raccorder le conduit au collet de conduit du ventilateur (Figure 4). Fixer en place à Préparation du Ventilateur d’évacuation l’aide de ruban ou de serre-joint.
  • Page 9: Couvercle Du Compartiment De Câblage

    SECTION 6 Couvercle du Complétion de l’installation Compartiment de Il est recommandé d’utiliser un scellant approprié pour le contact avec les matériaux Câblage de construction actuels et pour les besoins de la température de l’installation, afin d’empêcher les fuites d’air à partir des espaces non conditionnés. S’il y a des grands écarts entre le boîtier de l’appareil et le plafond, du matériel supplémentaire (tige de support, matériel de plafond) peut être nécessaire.
  • Page 10: Utilisation Et Entretien

    MODÈLES STANDARDS ET AVEC DÉTECTION D’HUMIDITÉ: Installer la grille en 2c. Pour ajuster le réglage, tandis que le capteur est continue de clignoter de l’étape 2b, pressant ensemble les deux extrémités des ressorts et en les installant dans les fentes appuyez sur le bouton le nombre de fois qui correspond à...
  • Page 11: Guide De Dépannage

    Guide de dépannage Trouble Cause Possible Solution Suggérée 1. Le ventilateur ne fonctionne pas lorsque 1a. Un fusible peut être grillé ou un disjoncteur Remplacer le fusible ou réinitialiser le disjoncteur. l’interrupteur est à la position en marche. peut être décle.nché. 1b.
  • Page 12: Diagramme Des Pièces De Remplacement

    DIAGRAMME DES PIÈCES DE REMPLACEMENT Tous les modèles # de pièce Qté. Description de remplacement Traverses de Montage 5S1299002 Assemblée de collier en métal de 6 po 5S5299100 Ressorts de la grille 5S1202046 Bride du plafond 5S1202050 Particularités des modèles ESB80SG, ESB130SG Canal de montage 5S1239024 Assemblée de la Soufflante...

Ce manuel est également adapté pour:

Esb serie

Table des Matières