IMPORTANT INSTRUCTIONS -
: AKLC701, AKLC702,
Models
AKLC703, AKLC709
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
electric shock and injury to person, including the following:
1. Read all instructions before installing or using exhaust fan.
2. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer.
3. Before servicing or cleaning the unit, switch power off at
service panel and lock the service disconnecting means to
prevent power from being switched on accidentally. When
the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the
service panel.
4. Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes
and standards, including fire-related construction.
5. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent back drafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA)
and the American Society for Heating, Refrigeration, and Air
Conditioning Engineers (ASHRAE), and the local code authorities.
CAUTION:
FOR GENERAL VENTILATING USE ONLY. DO
NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS
AND VAPORS.
210572200 Rev. A 6-06
OPERATING MANUAL
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
SAVE THESE INSTRUCTIONS
6. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
7. Ducted fans must always be vented to the outdoors.
8. This unit must be grounded.
9. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off
power unit.
WARNING:
DO NOT USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL
DEVICE.
WARNING:
A SHOWER STALL ENCLOSURE.
10. NEVER place a switch where it can be reached from a tub or
shower.
WARNING:
www.airkinglimited.com
Exhaust Fan with Light
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
DO NOT INSTALL OVER A TUB OR MOUNT IN
DO NOT USE IN KITCHENS
1 of 12

Publicité

Table des Matières
loading

Sommaire des Matières pour AirKing AKLC701

  • Page 7: Instructions Importantes - Manuel D'opération

    INSTRUCTIONS IMPORTANTES – MANUEL D’OPÉRATION : AKLC701, AKLC702, Ventilateur combiner, comprend Modèles AKLC703, AKLC709 lumière et ventilation LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À...
  • Page 8: Traverses De Montage

    INSTRUCTIONS D’INSTALLATION AVERTISSEMENT: VOUS ASSURER QUE L’ALIMENTATION " EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER " L’INSTALLATION. " " SECTION 1 Préparation du Ventilateur d’évacuation 1. Sortir le ventilateur de sa boite et confirmer que toutes les pièces sont présentes. En plus du ventilateur d’évacuation Figure 2 vous devriez avoir: 1 - Grille avec les Lentilles de l’éclairage...
  • Page 9 SECTION 4 Raccord Conduits AVERTISSEMENT: TOUS LES CONDUITS DOIVENT ÊTRE CONFORMES AUX CODES DU BÂTIMENT LOCAUX ET NATIONAUX. 1. Raccorder le conduit au collet de conduit du ventilateur (Figure 5). Fixer en place à l’aide de ruban ou de serre-joint. Toujours évacuer le ventilateur vers l’extérieur au travers de chapeau mural ou de toit.
  • Page 10 deux fils blancs du réceptacle de la lumière et le fil blanc du réceptacle du ventilateur d’évacuation. Raccorder le fil noir Crans provenant du commutateur mural aux deux fils rouge du réceptacle de la lumière et au fil noir du réceptacle du ventilateur d’évacuation. Raccorder le fil de mise à...
  • Page 11: Cause Possible

    3. Remplacement de l’ampoule: déconnecter l’alimentation de l’unité. Enlever les lentilles en verre de la grille en dévissant le bouton au haut des lentilles (Figure 11). Remplacer l’ampoule (les ampoules) avec une (des) ampoule(s) incandescente(s) à culot moyen de type A19 de 60 watts au maximum.
  • Page 12: Diagramme Des Pièces De Remplacement

    DIAGRAMME DES PIÈCES DE REMPLACEMENT # de pièce # de pièce Qté. Description de remplacement Qté. Description de remplacement Cabinet du ventilateur 5S1234001 Vis #10 de B 5S1299009 Traverses de Montage 5S1299002 Écrou 5S5204008 Collet / Clapet 5S1299006 Rondelle de Sécurité 5S5204007 Couvercle de Câble Externe 5S2299014...