Télécharger Imprimer la page

Siemens EQ.500 TP507RX4 Notice D'utilisation page 34

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 43
en Cleaning and servicing
the calc'nClean programme when your
appliance prompts you. The process
takes approx. 43 minutes.
Requirement: The brewing unit is
cleaned.
→ "Cleaning brewing unit", Page 31
Press
⁠ .
1.
Use
and
2.
and care" and press
Use
and
3.
"calc'nClean" and press
To start the programme, press
4.
a The display will guide you through
the programme.
Empty and insert the drip tray.
5.
If there is a water filter, remove it.
6.
Press
⁠ .
7.
Empty the water tank.
8.
Fill a container with 0.5 l lukewarm
9.
water.
Add a Siemens descaling tablet to
10.
the water and stir until the tablet is
fully dissolved.
Pour the descaling solution into the
11.
water tank up to the calc mark and
press
⁠ .
Place a container with a capacity of
12.
min. 0.5 l under the outlet system.
Place the end of the suction pipe in
13.
the container and press
a The descaling programme will run
for approx. 20 minutes.
Rinse the water tank.
14.
Press
⁠ .
15.
If there is a water filter, insert the wa-
16.
ter filter.
→ "Insert water filter", Page 22
Press
⁠ .
17.
Fill the tank with fresh water up to
18.
the "max" mark.
Press
⁠ .
19.
a The programme takes ap-
prox. 1 minute and rinses the appli-
ance.
34
to select "Cleaning
⁠ .
to select
⁠ .
⁠ .
Empty and insert the drip tray.
20.
Open the ground coffee compart-
21.
ment.
Place one Siemens cleaning tablet
22.
into the ground coffee compartment.
Close the ground coffee compart-
23.
ment and press
Place a container with a capacity of
24.
min. 0.5 l under the outlet system
and press
a The cleaning programme takes ap-
prox. 7 minutes.
⁠ .
Empty and insert the drip tray.
25.
Thoroughly clean the suction pipe of
26.
the milk system.
a The program has ended and the ap-
pliance is ready for operation.
⁠ .
⁠ .

Publicité

loading