Branch Kit 1:3
Procedure example
Manual address setup procedure
While the operation stops, change the
setup. (Be sure to stop the operation of the
unit.)
3
-2,
4
-2,
5
-2
7
1
1
Procedure
Push simultaneously
for 4 seconds or more. After a while, the
display part flashes as shown below. Check
the displayed CODE No. is [10].
When the CODE No. is other than [10],
push
button to erase the display and
repeat procedure from the first step.
(After pushing
the remote controller is not accepted for
approx.1 minute.)
(For a group control, No. of the firstly
displayed indoor unit becomes the
header unit.)
(* Display changes according to
the model No. of indoor unit.)
a
7
3
-1,
4
-1,
5
-1,
3
-3,
4
-3,
5
-3,
2,6
+
+
buttons
button, operation of
2
Procedure
Every pushing
unit No. in the group control is displayed in
order. Select the indoor unit of which setup
is changed.
At this time, the position of the indoor unit of
which setup is changed can be confirmed
because fan and louver of the selected
indoor unit operate.
3
Procedure
1. Using temp. setup
specify CODE No. [12].
(CODE No. [12]: Line address)
2. Using timer time
change the line address from [3] to [2].
3. Push
button.
At this time, the setup finishes when the
display changes from flashing to lighting.
Indoor unit No. before setup change is displayed.
4
Procedure
1. Using temp. setup
specify CODE No. [13].
(CODE No. [13]: Indoor address)
2. Using timer time
change the indoor address from [3] to
[2].
3. Push
button.
At this time, the setup finishes when the
display changes from flashing to lighting.
26