Troubleshooting Guide - AirKing AKF80LS Manuel D'utilisation

Masquer les pouces Voir aussi pour AKF80LS:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Figure 11
5. Restore power and test your installation.
SECTION 7
Use and Care
CAUTION:
MAKE SURE POWER IS SWITCHED OFF AT
SERVICE PANEL BEFORE SERVICING THE UNIT.
1. Cleaning the Grill: Remove grill and use a mild detergent,
such as dishwashing liquid, and dry with a soft cloth. NEVER
USE ANY ABRASIVE PADS OR SCOURING POWDERS.
Completely dry grill before reinstalling. Refer to instructions
in Section 6 Finishing the Installation , to reinstall grill.
2. Cleaning the Fan Assembly: Wipe all parts with a dry cloth
or gently vacuum the fan. NEVER IMMERSE ELECTRICAL
PARTS IN WATER.
Trouble
1. Fan does not operate when the switch is on.
2. Fan is operating, but air moves slower than normal.
3. Fan is operating louder than normal.
210572203 Rev. B 3-08

Troubleshooting Guide

Probable Cause
1a. A fuse may be blown or a circuit tripped.
1b. Connector plug from motor is not plugged in.
1c. Wiring is not connected properly.
1d. Motor has stopped operating.
2. Obstruction in the exhaust ducting.
3a. Motor is loose.
3b. Fan blade is hitting housing of unit.
www.airkinglimited.com
CAUTION:
ALLOW BULBS TO COOL BEFORE REPLACING.
3. Changing the Lamp: Disconnect power to the unit. Remove
grill by pulling downward on grill and squeezing grill springs
together to release from housing (Figure 12).
Fluorescent Bulb: Remove lamp by gently rocking lamp
back and forth while applying outward pressure to
release the lamp from the base. Replace with Air King
model 26WFL or a compatible CFM26W/GX24q/35 lamp.
Sylvania model: CF26DD/E/835
GE model: F26DBXT4SPX35/4P
Phillips model: PL-C 26W/835/4P/ALTO
Night Light: Unscrew night light bulb from socket and
replace with a 4 watt maximum type C7 (candelabra base)
night light bulb.
Figure 12
Suggested Remedy
1a. Replace fuse or reset circuit breaker.
1b. Turn off power to unit. Remove Grill and plug motor into receptacle
in housing. Restore power to unit.
1c. Turn off power to unit. Check that all wires are connected.
1d. Replace motor.
2. Check for any obstructions in the ducting. The most common are bird nests
in the roof cap or wall cap where the fan exhausts to the outside.
3a. Turn off power to unit. Remove grill and check that all screws are fully
tightened. Restore power to unit.
3b. Call your dealer for service.